Kuapo Hirschmann BRS40-00209999-STCZ99HHSES
Wehewehe Pōkole:
ʻO ka Hirschmann BOBCAT Switch ka mea mua o kona ʻano e hiki ai ke kamaʻilio manawa maoli me ka hoʻohana ʻana iā TSN. No ke kākoʻo pono ʻana i nā koi kamaʻilio manawa maoli e hoʻonui nei i nā wahi ʻoihana, he mea nui kahi iwi kuamoʻo pūnaewele Ethernet ikaika. ʻAe kēia mau kuapo i hoʻokele liʻiliʻi ʻia no ka hoʻonui ʻana i nā hiki bandwidth ma ka hoʻoponopono ʻana i kāu mau SFP mai 1 a 2.5 Gigabit - ʻaʻohe pono o ka hoʻololi ʻana i ka mīkini.
Nā kikoʻī huahana
Nā Lepili Huahana
Lā Kūʻai
Huahana wehewehe
| Wehewehena | Hoʻololi ʻoihana i mālama ʻia no ka DIN Rail, hoʻolālā fanless ʻAno Gigabit āpau |
| Mana Polokalamu | HiOS 09.6.00 |
| ʻAno a me ka nui o ke awa | 20 mau awa i ka huina: 20x 10/100/1000BASE TX / RJ45 |
ʻOi aku Nā ʻaoʻao
| Hoʻopili mana/hōʻailona | 1 x poloka terminal plug-in, 6-pin |
| Hoʻokomo kikohoʻe | 1 x poloka terminal plug-in, 2-pin |
| Hoʻokele Kūloko a me ka Hoʻololi Hāmeʻa | USB-C |
| Pālua wili (TP) | 0 - 100 mika |
Pūnaewele ka nui - ka hiki ke hoʻokuʻu ʻia
| ʻO ke ʻano o ka laina - / hōkū | kekahi |
Mana nā koi
| Anakahi Hana | 2 x 12 VDC ... 24 VDC |
| Ka hoʻohana ʻana i ka mana | 17 Komohana |
| Ka hoʻopuka mana ma BTU (IT)/h | 58 |
| Ke hoʻololi nei | Ke aʻo ʻana o VLAN kūʻokoʻa, ka ʻelemakule wikiwiki, nā hoʻokomo helu wahi Unicast/Multicast paʻa, QoS / Port Prioritization (802.1D/p), TOS/DSCP Prioritization, Interface Trust Mode, CoS Queue Management, Queue-Shaping / Max. Queue Bandwidth, Flow Control (802.3X), Egress Interface Shaping, Ingress Storm Protection, Jumbo Frames, VLAN (802.1Q), GARP VLAN Registration Protocol (GVRP), Voice VLAN, GARP Multicast Registration Protocol (GMRP), IGMP Snooping/Querier no VLAN (v1/v2/v3), Unknown Multicast Filtering, Multiple VLAN Registration Protocol (MVRP), Multiple MAC Registration Protocol (MMRP), Multiple Registration Protocol (MRP) |
| Hoʻonui hou ʻana | HIPER-Apo (Apo Kuapo), Hoʻohui Loulou me LACP, Kākoʻo Loulou, Media Redundancy Protocol (MRP) (IEC62439-2), Hoʻohui Pūnaewele Redundant, RSTP 802.1D-2004 (IEC62439-1), Nā Mālama RSTP |
| Hoʻokele | Kākoʻo Kiʻi Polokalamu Pālua, TFTP, SFTP, SCP, LLDP (802.1AB), LLDP-MED, SSHv2, HTTP, HTTPS, Traps, SNMP v1/v2/v3, Telnet, Hoʻokele IPv6, Kikowaena OPC UA |
| Nā Hōʻailona | ʻIke ʻana i ka hakakā o ka helu wahi hoʻokele, Hoʻolaha MAC, Hoʻokaʻaʻike Hōʻailona, Hōʻike kūlana o ka hāmeʻa, TCPDump, LEDs, Syslog, Hoʻopaʻa inoa mau ʻana ma ACA, Nānā ʻana i ke awa me ka hoʻopau ponoʻī, ʻIke ʻana i ka Link Flap, ʻIke ʻana i ka overload, ʻIke ʻana i ka Duplex Mismatch, Nānā ʻana i ka wikiwiki o ka loulou a me ka Duplex, RMON (1,2,3,9), Mirroring Port 1:1, Mirroring Port 8:1, Mirroring Port N:1, Mirroring Port N:2, ʻIke ʻōnaehana, Nā hoʻāʻo ponoʻī ma ka hoʻomaka anuanu, Hoʻāʻo uwea keleawe, Hoʻokele SFP, Kūkākūkā nānā hoʻonohonoho, Switch Dump |
| Hoʻonohonoho ʻana | Hoʻihoʻi Hoʻonohonoho ʻakomi (roll-back), Configuration Fingerprint, Text-based Configuration File (XML), Backup config ma kahi kikowaena mamao i ka wā e mālama ai, Clear config akā mālama i nā hoʻonohonoho IP, BOOTP/DHCP Client me Auto-Configuration, DHCP Server: no kēlā me kēia Port, DHCP Server: Pools no kēlā me kēia VLAN, AutoConfiguration Adapter ACA21/22 (USB), HiDiscovery, kākoʻo USB-C Management, Command Line Interface (CLI), CLI Scripting, lawelawe ʻana i ka palapala CLI ma luna o ENVM i ka wā boot, Kākoʻo MIB piha-hiʻona, Kōkua pili i ka pōʻaiapili, Hoʻokele e pili ana i ka HTML5 |
| Palekana | Hōʻoia ʻia ʻo ISASecure CSA / IEC 62443-4-2, Palekana Puka ma muli o MAC, Mana Komo ma muli o ke Puka me 802.1X, VLAN Malihini/ʻAʻole i hōʻoia ʻia, Kikowaena Hōʻoia Hoʻohui (IAS), Hoʻonohonoho VLAN RADIUS, Kāohi ʻana i ka Hōʻole ʻana i ka Hana, DoS Prevention Drop Counter, ACL ma muli o VLAN, ACL ma muli o Ingress VLAN, ACL kumu, Loaʻa i ka Hoʻokele i kaupalena ʻia e VLAN, Hōʻike Palekana Hāmeʻa, Ala Audit, CLI Logging, Hoʻokele Palapala Hōʻoia HTTPS, Loaʻa Hoʻokele i kaupalena ʻia, Banner Hoʻohana Kūpono, Kulekele ʻŌlelo Huna hiki ke hoʻonohonoho ʻia, Helu Hoʻonohonoho o nā Hoʻāʻo Komo, Logging SNMP, Nā Pae Kuleana He nui, Hoʻokele Mea Hoʻohana Kūloko, Hōʻoia Mamao ma o RADIUS, Laka Moʻokāki Mea Hoʻohana, Hoʻololi ʻōlelo huna ma ke komo mua ʻana |
| Hoʻonohonoho manawa | Uaki Moakaka PTPv2 ʻelua-ʻanuʻu, Uaki Palena PTPv2, BC me ka hiki i 8 Sync / s, 802.1AS, Uaki Manawa Maoli Buffered, SNTP Client, Kikowaena SNTP |
| Nā ʻIkepili ʻOihana | ʻO ka ʻōnaehana EtherNet/IP, ʻōnaehana IEC61850 (MMS Server, Switch Model), Modbus TCP, ʻōnaehana PROFINET |
| Nā mea like ʻole | Hoʻokele IO Kikohoʻe, Keʻa Uea Manual, Hoʻopau i ka Mana o ke awa |
Nā kūlana ambient
| MTBF (Telecordia SR-332 Pukana 3) @ 25°C | 1 639 262 hola |
| Mahana hana | 0-+60 |
| Mahana mālama/lawe | -40-+70 °C |
| Ka makū pili (ʻaʻole e hoʻopūʻiwa) | 1- 95% |
Ke kūkulu ʻana i ka mīkini
| Nā Ana (WxHxD) | 109 mm x 138 mm x 115 mm |
| Kaumaha | 1060 g |
| Hale noho | PC-ABS |
| Ke kau ʻana | ʻAlanui DIN |
| Papa palekana | IP30 |
Nā Kumu Hoʻohālike i Loaʻa no ka Hirschmann BRS40 BOBCAT Series
BRS40-0012OOOO-STCZ99HHSESXX.X.XX
BRS40-0008OOOO-STCZ99HHSESXX.X.XX
BRS40-00169999-STCZ99HHSESXX.X.XX
BRS40-0020OOOO-STCZ99HHSESXX.X.XX
BRS40-00209999-STCZ99HHSESXX.X.XX
BRS40-00249999-STCZ99HHSESXX.X.XX
BRS40-0024OOOO-STCZ99HHSESXX.X.XX
Nā huahana pili
-
Papa Hoʻopau Hirschmann MIPP/AD/1L9P
Wehewehe huahana Huahana: MIPP/AD/1S9P/XXXX/XXXX/XXXX/XXXX/XXXX/XXXX/XX Mea hoʻonohonoho: MIPP - Modular Industrial Patch Panel configurator Wehewehe huahana Wehewehe ʻO MIPP™ kahi panela hoʻopau a me ka hoʻopili ʻana i nā kaula e hiki ai ke hoʻopau a hoʻopili ʻia i nā lako hana e like me nā kuapo. Mālama kona hoʻolālā paʻa i nā pilina ma aneane nā noi ʻoihana. Hele mai ʻo MIPP™ ma ke ʻano he Fibe...
-
ʻO Hirschmann GECKO 8TX/2SFP Lite Hoʻokele ʻia ʻoihana...
Wehewehena Wehewehena huahana ʻAno: GECKO 8TX/2SFP Wehewehena: Lite Managed Industrial ETHERNET Rail-Switch, Ethernet/Fast-Ethernet Switch me Gigabit Uplink, Store and Forward Switching Mode, fanless design ʻĀpana Helu: 942291002 ʻAno awa a me ka nui: 8 x 10BASE-T/100BASE-TX, TP-cable, RJ45-sockets, auto-crossing, auto-negotiation, auto-polarity, 2 x 100/1000 MBit/s SFP A...
-
Kuapo Liʻiliʻi Hirschmann RS30-2402O6O6SDAE
Lā Kūʻai Wehewehe huahana Wehewehe 26 awa Gigabit/Fast-Ethernet-Switch (2 x Gigabit Ethernet, 24 x Fast Ethernet), hoʻokele ʻia, polokalamu Layer 2 Hoʻonui ʻia, no ka hoʻololi ʻana i ka hale kūʻai a me ka hoʻokele mua ʻana o ke kaʻaahi DIN, hoʻolālā fanless ʻAno awa a me ka nui 26 mau awa i ka huina, 2 mau awa Gigabit Ethernet; 1. uplink: Gigabit SFP-Slot; 2. uplink: Gigabit SFP-Slot; 24 x maʻamau 10/100 BASE TX, RJ45 Nā Interfaces ʻē aʻe Hoʻopili mana/hōʻailona ...
-
Hirschmann RSP20-11003Z6TT-SK9V9HSE2S ʻOihana...
ʻO ka wehewehe huahana ʻO Hirschmann RSP20-11003Z6TT-SK9V9HSE2S he 11 mau awa i ka huina: 8 x 10/100BASE TX / RJ45; 3 x SFP slot FE (100 Mbit/s) kuapo. Hōʻike ka moʻo RSP i nā kuapo DIN rail ʻoihana paʻakikī a hoʻokele paʻa me nā koho wikiwiki Fast a me Gigabit. Kākoʻo kēia mau kuapo i nā protocol redundancy piha e like me PRP (Parallel Redundancy Protocol), HSR (High-availability Seamless Redundancy), DLR (...
-
Hirschmann RS20-0800S2T1SDAU ʻOihana Hoʻokele ʻole ʻia...
Hoʻolauna ʻO nā kuapo Ethernet i mālama ʻole ʻia ʻo RS20/30 Hirschmann RS20-0800S2S2SDAUHC/HH Nā hiʻohiʻona i helu ʻia RS20-0800T1T1SDAUHC/HH RS20-0800M2M2SDAUHC/HH RS20-0800S2S2SDAUHC/HH RS20-1600M2M2SDAUHC/HH RS20-1600S2S2SDAUHC/HH RS30-0802O6O6SDAUHC/HH RS30-1602O6O6SDAUHC/HH RS20-0800S2T1SDAUHC RS20-1600T1T1SDAUHC RS20-2400T1T1SDAUHC
-
Kuapo Hoʻokele ʻole ʻia ʻo Hirschmann SPR40-1TX/1SFP-EEC
Lā Kūʻai Wehewehe huahana Wehewehe ʻAʻole i mālama ʻia, Industrial ETHERNET Rail Switch, hoʻolālā fanless, mālama a me ke ʻano hoʻololi mua, interface USB no ka hoʻonohonoho ʻana, ʻano piha Gigabit Ethernet Port a me ka nui 1 x 10/100/1000BASE-T, uwea TP, RJ45 sockets, auto-crossing, auto-negotiation, auto-polarity, 1 x 100/1000MBit/s SFP Nā Interfaces ʻOi aku ka lako mana/hoʻopili hōʻailona 1 x poloka terminal plug-in, 6-pin ...


