Hoʻololi ʻo Hirschmann DRAGON MACH4000-48G+4X-L3A-UR
ʻO ka wehewehe pōkole:
Hoʻololi ʻo Gigabit Ethernet Backbone piha me nā awa 48x GE + 4x 2.5/10 GE, hoʻolālā modular, hoʻonohonoho ʻia nā mea pā, nā panela makapō no ke kāleka laina a me nā kau lako mana i hoʻokomo ʻia, nā hiʻohiʻona Layer 3 HiOS holomua, unicast routing.
Huahana Huahana
Huahana Huahana
Lā Hoʻolaha
Huahanawehewehe
ʻAno: | DRAGON MACH4000-48G+4X-L3A-UR |
inoa: | DRAGON MACH4000-48G+4X-L3A-UR |
wehewehe: | Hoʻololi ʻia ʻo Gigabit Ethernet Backbone piha me ka lako mana redundant kūloko a hiki i nā awa 48x GE + 4x 2.5/10 GE, hoʻolālā modular a me nā hiʻohiʻona Layer 3 HiOS holomua, unicast routing. |
Mana polokalamu: | HiOS 09.0.06 |
Helu hapa: | 942154002 |
ʻAno awa a me ka nui: | Awa i ka huina a hiki i 52, wae kumu 4 mau awa pa'a: 4x 1/2.5/10 GE SFP+, Modular: 48x FE/GE mau awa hiki ke hoonuiia me eha mau puka modula media, 12x FE/GE puka no ka module |
ʻOi aku Nā mea hoʻohana
V.24 interface: | 1 x RJ45 kumu |
Kāleka SD: | 1 x e hoʻohui i ka mea hoʻopili hoʻonohonoho ʻokoʻa ACA31 (SD) |
Pili USB: | 1 x USB no ka hoʻopili ʻana i ka adapter hoʻonohonoho ʻokoʻa ACA22-USB |
Ka manakoi
Voltage hana: | PSU wae komo: 100 - 240 V AC; Hiki ke hoʻohana ʻia ka hoʻololi me 1 a i ʻole 2 mau ʻāpana PSU hiki ke hoʻololi ʻia (e kauoha ʻia ʻo ia) |
Hoʻohana mana: | 80 W (me nā transceiver SFP + 1 PSU + Module pā) |
lako polokalamu
Ke hoʻololi nei: | ʻO ke aʻo ʻana VLAN kūʻokoʻa, ka ʻelemakule wikiwiki, nā helu helu helu Unicast/Multicast, QoS / Port Prioritization (802.1D/p), TOS/DSCP Prioritization, Interface Trust Mode, CoS Queue Management, IP Ingress DiffServ Classification and Policing, IP Egress DiffServ Classification and Policing, Queue-Shaping. ʻO ka Lālani Queue, Ka Mana Kahe (802.3X), Ka Hoʻohālikelike ʻana o ka Egress Interface Shaping, Hoʻopaʻa ʻana i ka ʻino, ʻo Jumbo Frames, VLAN (802.1Q), VLAN ma muli o ka Protocol, VLAN Unware Mode, GARP VLAN Registration Protocol (GVRP), Voice VLAN, MAC-based VLAN, IP subnet-based VLAN, GARPto Protocol Multicast (SGMRPto Protocol) no VLAN (v1/v2/v3), ʻAʻole ʻike ʻia ʻo Multicast Filtering, Multiple VLAN Registration Protocol (MVRP), Multiple MAC Registration Protocol (MMRP), Multiple Registration Protocol (MRP), Layer 2 Loop Protection |
Hoʻokuʻu ʻia: | HIPER-Ring (Ring Switch), HIPER-Ring over Link Aggregation, Link Aggregation me LACP, Link Backup, Media Redundancy Protocol (MRP) (IEC62439-2), MRP ma luna o ka Link Aggregation, Redundant Network Coupling, Sub Ring Manager, RSTP 802.1D-2004 (IEC62439), RSTP 802.1D-2004 (IEC62439) VRRP, VRRP Tracking, HiVRRP (VRRP hoʻonui) |
Hooponopono: | Kākoʻo kiʻi polokalamu ʻelua, TFTP, SFTP, SCP, LLDP (802.1AB), LLDP-MED, SSHv2, V.24, HTTP, HTTPS, Traps, SNMP v1/v2/v3, Telnet, DNS Client, OPC-UA Server |
ʻIkepili: | ʻIke Kūʻē Kūʻē Manaʻo, Hoʻolaha MAC, Hoʻokaʻaʻike Hōʻailona, Hōʻike Kūlana Pūnaewele, TCPDump, LED, Syslog, Hoʻopaʻa mau i ka ACA, Hoʻolaha leka uila, nānā ʻana i ke awa me ka hoʻopau ʻole, Link Flap Detection, Overload Detection, Duplex Mismatch Detection, Link Speed and Duplex Monitoring, RMON (1,2,3, Mirroring Port), RMON (1,2,3, Mirroring, Portringing) 8:1, Hōʻike ʻia ʻo Port N:1, RSPAN, SFLOW, VLAN Mirroring, Port Mirroring N:2, ʻIke Pūnaehana, Hoʻāʻo ponoʻī ma ka hoʻomaka anu, hoʻāʻo ʻo Copper Cable, Management SFP, Configuration Check Dialog, Switch Dump, Snapshot Configuration Feature |
Hoʻonohonoho: | Hoʻopau i ka hoʻololi ʻana (roll-back), ka manamana lima hoʻonohonoho, ka faila hoʻonohonoho kikokikona (XML), ka mea kūʻai aku ʻo BOOTP/DHCP me ka hoʻonohonoho ʻokoʻa, DHCP Server: ma kēlā me kēia Port, Server DHCP: Pools ma VLAN, AutoConfiguration Adapter ACA31 (kāleka SD), AutoConfiguration Adapter ACA21/22 (USB), Hiʻohiʻona Hoʻololi, DHCP Option (USB) Interface (CLI), CLI Scripting, Kākoʻo MIB piha piha, Manaʻo Pūnaewele, Kōkua Pilikino |
Palekana: | ʻO ka palekana Port-based MAC, Port-based Access Control with 802.1X, Guest/Authenticated VLAN, Integrated Authentication Server (IAS), RADIUS VLAN Assignment, RADIUS Policy Assignment, Multi-Client Authentication per Port, MAC Authentication Bypass, DHCP Snooping, IP Source Guardres, Dynamic ARP-of-Inspection MAC, Denial ARP-Inspection. ACL, Egress MAC-based ACL, Ingress IPv4-based ACL, Egress IPv4-based ACL, Time-based ACL, VLAN-based ACL, Ingress VLAN-based ACL, Egress VLAN-based ACL, ACL Flow-based Limiting, Access to Management i kaupalena ʻia e VLAN, Device Security Indication, Audit Trail, Hoʻohana i ka palapala hōʻoia CLI, Hoʻopaʻa ʻana i ka palapala hōʻoia, Hoʻopaʻa ʻia ʻo HTTPS. Kulekele ʻōlelo huna hiki ke hoʻonohonoho ʻia, ka helu hiki ke hoʻonohonoho ʻia o ka hoʻāʻo ʻana, SNMP Logging, Multiple Privilege Levels, Local User Management, Remote Authentication by RADIUS, User Account Locking, Password Change on first login |
Hoʻonohonoho manawa: | ʻElua ʻanuʻu ʻelua ʻanuʻu ʻo PTPv2, uaki palena ʻo PTPv2, uaki manawa maoli i hoʻopaʻa ʻia, mea kūʻai aku SNTP, kikowaena SNTP. |
Nā mea like ʻole: | Kaʻa Uea Manuahi, Ka Mana Awa i lalo |
Alanui: | IP/UDP Helper, Holo Wire-Speed Routing, Port-based Router Interfaces, VLAN-based Router Interfaces, Loopback Interface, ICMP Filter, Net-directed Broadcasts, OSPFv2, RIP v1/v2, ICMP Router Discovery (IRDP), Equal Cost Multiple Path (ECMP), Static ARP Routing, Static Unicast Routing, Static Unicast Routing v1/v2/v3, IGMP Proxy (Ke alahele lehulehu) |
Ambientkūlana
MTBF (Telecordia SR-332 Puka 3) @ 25°C: | 1 281 583 h |
Mahana hana: | 0-+60 °C |
Ka wela o ka mālama ʻana/kaʻi: | -40-+70 °C |
ʻO ka haʻahaʻa haʻahaʻa (condensing ʻole): | 10-95 % |
Mechanical kūkulu hale
Ana (WxHxD): | 480 mm x 88 mm x 445 mm |
Ke kau nei: | 19" keena hoʻomalu |
Papa pale: | IP20 |
Nā ʻāpono
Kūlana kumu: | C-Tick, CE, EN61131 |
Palekana o nā mea hoʻokele ʻenehana: | cUL61010-1/-2-201, EN60950-1 |
Kaʻahele: | EN 50121-4 |
Nā ʻano like ʻole
'ikamu # | ʻAno |
942154002 | DRAGON MACH4000-48G+4X-L3A-UR |
Hirschmann DRAGON MACH4000 Series Loaʻa nā Models
DRAGON MACH4000-48G+4X-L2A
DRAGON MACH4000-48G+4X-L3A-UR
DRAGON MACH4000-48G+4X-L3A-MR
DRAGON MACH4000-52G-L2A
DRAGON MACH4000-52G-L3A-UR
DRAGON MACH4000-52G-L3A-MR
Nā huahana pili
-
Hoʻololi ʻo Hirschmann GRS106-16TX/14SFP-2HV-3AUR
Lā Kūʻai ʻO ka wehewehe ʻana o ka huahana ʻAno GRS106-16TX/14SFP-2HV-3AUR (Ke code huahana: GRS106-6F8F16TSGGY9HHSE3AURXX.X.XX) Hōʻike GREYHOUND 105/106 Series, Managed Industrial Switch, fanless design, 19" rack mount, e like me I.3EEE 80" 6x1/2.5/10GE +8x1/2.5GE +16xGE Design Software Version HiOS 9.4.01 Helu Mahele 942287016 ʻAno awa a me ka nui 30 Puka i ka huina, 6x GE/2.5GE/10GE SFP(+) slot + 8x GE/2.5GE SFP slot + 8x GE/2.5GE...
-
Hirschmann EAGLE20-0400999TT999SCCZ9HSEOP Alaula
ʻO ka wehewehe ʻana o ka huahana ʻO ka wehewehe ʻana i ka pā ahi ʻoihana a me ka mea hoʻokele palekana, DIN rail i kau ʻia, hoʻolālā ʻole. ʻAno Ethernet wikiwiki. ʻAno awa a me ka nui 4 awa i ka huina, Ports Fast Ethernet: 4 x 10/100BASE TX / RJ45 ʻOi aku nā Interfaces V.24 interface 1 x RJ11 socket SD-cardslot 1 x SD cardslot no ka hoʻopili ʻana i ka mea hoʻopili hoʻonohonoho auto ACA31 USB interface 1 x USB e hoʻohui i ka adapter auto-configuration A...
-
Hirschmann BRS20-8TX/2FX (Ka helu huahana: BRS20-1...
Lā Kūʻai ʻO ka wehewehe ʻana o ka huahana Type BRS20-8TX/2FX (Product code: BRS20-1000M2M2-STCY99HHSESXX.X.XX) Wehewehena Managed Industrial Switch for DIN Rail, fanless design Fast Ethernet Type Software Version HiOS10.0.00 Part Number 942170004 Port type and quantity 10 ASE. TX / RJ45; 2x 100Mbit/s puluniu; 1. Uplink: 1 x 100BASE-FX, MM-SC ; 2. Ka loulou i luna: 1 x 100BAS...
-
Hirschmann ACA21-USB (EEC) mea hoʻopili
ʻO ka wehewehe ʻana i ka huahana ʻAno: ACA21-USB EEC Hōʻike: Auto-configuration adapter 64 MB, me ka pilina USB 1.1 a me ka lōʻihi o ka mahana wela, e mālama i ʻelua mau ʻano like ʻole o ka ʻikepili hoʻonohonoho a me nā polokalamu hana mai ka hoʻololi pili. Hiki iā ia ke hana maʻalahi i nā hoʻololi hoʻokele a hoʻololi koke ʻia. Helu Mahele: 943271003 Ka lōʻihi o ke kelepona: 20 cm ʻoi aku ka pilina...
-
Hirschmann BRS40-0020OOOO-STCZ99HHSES Hoʻololi
ʻO ka wehewehe ʻana i ka lā Commerial Date Configurator ʻO ka Hirschmann BOBCAT Switch ka mea mua o kāna ʻano e hiki ai ke kamaʻilio manawa maoli me ka hoʻohana ʻana iā TSN. No ke kākoʻo maikaʻi ʻana i ka hoʻonui ʻana i nā koi kamaʻilio manawa maoli i nā ʻoihana ʻoihana, pono ka iwi kuamoʻo Ethernet ikaika. Hāʻawi kēia hoʻololi hoʻokele paʻa i ka hiki ke hoʻonui i ka bandwidth ma o ka hoʻoponopono ʻana i kāu SFP mai 1 a 2.5 Gigabit - ʻaʻole pono e hoʻololi i ka appli ...
-
Hirschmann GRS106-24TX/6SFP-2HV-3AUR GREYHOUND ...
Lā Kūʻai ʻO ka wehewehe ʻana o ka huahana ʻAno GRS106-24TX/6SFP-2HV-3AUR (Ke code huahana: GRS106-6F8T16TSGGY9HHSE3AURXX.X.XX) Hōʻike GREYHOUND 105/106 Series, Managed Industrial Switch, fanless design, 19" rack mount, e like me I.3EEE 802. 6x1/2.5/10GE +8x1/2.5GE +16xGE Pūnaehana Pūnaehana HiOS 10.0.00 Helu Mahele 942287015 ʻAno awa a me ka nui 30 Puka i ka huina, 6x GE/2.5GE/10GE SFP(+) slot + 8x FE/GE/2.5GE 1...