| ʻAno: | DRAGON MACH4000-48G+4X-L3A-UR |
| Inoa: | DRAGON MACH4000-48G+4X-L3A-UR |
| Wehewehena: | ʻO ka Gigabit Ethernet Backbone Switch piha me ka lako mana redundant kūloko a hiki i ka 48x GE + 4x 2.5/10 GE ports, hoʻolālā modular a me nā hiʻohiʻona Layer 3 HiOS holomua, unicast routing |
| Mana Polokalamu: | HiOS 09.0.06 |
| Helu ʻĀpana: | 942154002 |
| ʻAno awa a me ka nui: | ʻO ka huina o nā awa a hiki i 52, ʻĀpana kumu 4 mau awa paʻa: 4x 1/2.5/10 GE SFP+, Modular: 48x mau awa FE/GE hiki ke hoʻonui ʻia me ʻehā mau wahi module media, 12x mau awa FE/GE no kēlā me kēia module |
ʻOi aku Nā ʻaoʻao
| Hoʻohui V.24: | 1 x RJ45 kumu hoʻokomo |
| Kaʻa kāleka SD: | 1 x e hoʻohui i ka mea hoʻololi hoʻonohonoho ponoʻī ACA31 (SD) |
| Hoʻohui USB: | 1 x USB e hoʻohui i ka mea hoʻololi hoʻonohonoho ponoʻī ACA22-USB |
Mananā koi
| Anakahi Hana: | Hoʻokomo ʻāpana PSU: 100 - 240 V AC; hiki ke hoʻohana ʻia ke kuapo me 1 a i ʻole 2 mau ʻāpana PSU hiki ke pani ʻia ma ke kahua (e kauoha ʻokoʻa ʻia) |
| Ka hoʻohana ʻana i ka mana: | 80 W (me nā mea hoʻoili SFP + 1 PSU + module Fan) |
Polokalamu
|
Ke hoʻololi nei: | Ke aʻo ʻana o VLAN kūʻokoʻa, ka ʻelemakule wikiwiki, nā hoʻokomo helu wahi Unicast/Multicast Static, QoS / Port Prioritization (802.1D/p), TOS/DSCP Prioritization, Interface Trust Mode, CoS Queue Management, IP Ingress DiffServ Classification and Policing, IP Egress DiffServ Classification and Policing, Queue-Shaping / Max. Queue Bandwidth, Flow Control (802.3X), Egress Interface Shaping, Ingress Storm Protection, Jumbo Frames, VLAN (802.1Q), Protocol-based VLAN, VLAN Unaware Mode, GARP VLAN Registration Protocol (GVRP), Voice VLAN, MAC-based VLAN, IP subnet-based VLAN, GARP Multicast Registration Protocol (GMRP), IGMP Snooping/Querier no VLAN (v1/v2/v3), Unknown Multicast Filtering, Multiple VLAN Registration Protocol (MVRP), Multiple MAC Registration Protocol (MMRP), Multiple Registration Protocol (MRP), Layer 2 Loop Protection |
| Hoʻonui hou ʻana: | HIPER-Ring (Apo Kuapo), HIPER-Ring ma luna o ka Hoʻohuihui Loulou, Hoʻohuihui Loulou me LACP, Kākoʻo Loulou, Media Redundancy Protocol (MRP) (IEC62439-2), MRP ma luna o ka Hoʻohuihui Loulou, Hoʻohuihui Pūnaewele Redundant, Luna Hoʻokele Apo Liʻiliʻi, RSTP 802.1D-2004 (IEC62439-1), MSTP (802.1Q), RSTP Guards, VRRP, VRRP Tracking, HiVRRP (nā hoʻomaikaʻi VRRP) |
| Hoʻokele: | Kākoʻo Kiʻi Polokalamu Pālua, TFTP, SFTP, SCP, LLDP (802.1AB), LLDP-MED, SSHv2, V.24, HTTP, HTTPS, Traps, SNMP v1/v2/v3, Telnet, DNS Client, OPC-UA Server |
| Nā hōʻailona: | ʻIke ʻana i ka hakakā o ka helu wahi hoʻokele, Hoʻolaha MAC, Hoʻokaʻaʻike Hōʻailona, Hōʻike kūlana o ka hāmeʻa, TCPDump, LEDs, Syslog, Hoʻopaʻa inoa mau ʻana ma ACA, Hoʻolaha leka uila, Nānā ʻana i ke awa me ka hoʻopau ponoʻī, ʻIke ʻana i ka Link Flap, ʻIke ʻana i ka overload, ʻIke ʻana i ka Duplex Mismatch, Nānā ʻana i ka wikiwiki o ka loulou a me ka Duplex, RMON (1,2,3,9), Mirroring Port 1:1, Mirroring Port 8:1, Mirroring Port N:1, RSPAN, SFLOW, Mirroring VLAN, Mirroring Port N:2, ʻIke ʻōnaehana, Nā hoʻāʻo ponoʻī ma ka hoʻomaka anuanu, Hoʻāʻo uwea keleawe, Hoʻokele SFP, Kūkākūkā nānā hoʻonohonoho, Switch Dump, Hiʻohiʻona hoʻonohonoho snapshot |
| Hoʻonohonoho ʻana: | Hoʻihoʻi Hoʻonohonoho ʻAkomi (ʻōwili hope), Manamana Lima Hoʻonohonoho, Waihona Hoʻonohonoho i hoʻokumu ʻia i ka kikokikona (XML), BOOTP/DHCP Client me ka Hoʻonohonoho ʻAkomi, Kikowaena DHCP: no kēlā me kēia awa, Kikowaena DHCP: Nā loko no kēlā me kēia VLAN, Mea Hoʻololi Hoʻonohonoho ʻAkomi ACA31 (kāleka SD), Mea Hoʻololi Hoʻonohonoho ʻAkomi ACA21/22 (USB), HiDiscovery, DHCP Relay me ke koho 82, Interface Laina Kauoha (CLI), Kākau ʻana o CLI, Kākoʻo MIB piha-hiʻona, Hoʻokele Pūnaewele, Kōkua Pili i ka Pōʻaiapili |
|
Palekana: | Palekana Puka ma muli o MAC, Mana Komo ma muli o ke Puka me 802.1X, VLAN Malihini/ʻAʻole i hōʻoia ʻia, Kikowaena Hōʻoia Hoʻohui (IAS), Hoʻonohonoho VLAN RADIUS, Hoʻonohonoho Kulekele RADIUS, Hōʻoia Multi-Client no kēlā me kēia Puka, MAC Authentication Bypass, DHCP Snooping, IP Source Guard, Nānā ARP Dynamic, Kāohi ʻana i ka Hōʻole ʻana i ka Hana, LDAP, Ingress MAC-based ACL, Egress MAC-based ACL, Ingress IPv4-based ACL, Egress IPv4-based ACL, Time-based ACL, VLAN-based ACL, Ingress VLAN-based ACL, Egress VLAN-based ACL, ACL Ka Palena ʻana ma muli o ke Kahe, Loaʻa i ka Hoʻokele i kaupalena ʻia e VLAN, Hōʻike Palekana Mea Hana, Ala Audit, CLI Logging, Hoʻokele Palapala Hōʻoia HTTPS, Loaʻa Hoʻokele i kaupalena ʻia, Banner Hoʻohana Kūpono, Kulekele ʻŌlelo Huna Hiki ke Hoʻonohonoho ʻia, Helu Hoʻonohonoho ʻia o nā Hoʻāʻo Komo, SNMP Logging, Nā Pae Kuleana He nui, Hoʻokele Mea Hoʻohana Kūloko, Hōʻoia Mamao ma o RADIUS, Mea Hoʻohana Ka laka ʻana i ka moʻokāki, ka hoʻololi ʻana i ka ʻōlelo huna i ka wā e komo mua ai |
| Hoʻonohonoho manawa: | Uaki Moakaka PTPv2 ʻelua-ʻanuʻu, Uaki Palena PTPv2, Uaki Manawa Maoli i Hoʻopaʻa ʻia, Mea Kūʻai SNTP, Kikowaena SNTP |
| Nā mea like ʻole: | Keʻa ʻana o ke kaula lima, ka mana o ke awa i lalo |
| Ke alahele: | Kōkua IP/UDP, Alanui wikiwiki piha o ka uea, Nā pilina alahele e pili ana i ke awa, Nā pilina alahele e pili ana i ka VLAN, Loopback Interface, Kānana ICMP, Nā hoʻolaha i kuhikuhi ʻia e ka ʻupena, OSPFv2, RIP v1/v2, ICMP Router Discovery (IRDP), Alanui like ʻole o ke kumukūʻai (ECMP), Alanui Unicast Static, Proxy ARP, Nānā Alanui Static, IGMP v1/v2/v3, IGMP Proxy (Alanui Multicast) |
Kaiapuninā kūlana
| MTBF (Telecordia SR-332 Helu 3) @ 25°C: | 1 281 583 hola |
| Mahana hana: | 0-+60 °C |
| Mahana mālama/lawe: | -40-+70 °C |
| Ka makū pili (ʻaʻole e hoʻopūʻiwa): | 10-95% |
Mīkini kūkulu ʻana
| Nā Ana (WxHxD): | 480 mm x 88 mm x 445 mm |
| Ke kau ʻana: | Keʻena hoʻokele 19" |
| Papa palekana: | IP20 |
Nā ʻāpono
| Kūlana Kumu: | C-Tick, CE, EN61131 |
| Palekana o nā lako hana hoʻomalu ʻoihana: | cUL61010-1/-2-201, EN60950-1 |
| Ka halihali: | EN 50121-4 |
Nā ʻano like ʻole
| Mea # | ʻAno |
| 942154002 | DRAGON MACH4000-48G+4X-L3A-UR |
Nā Kumu Hoʻohālike i Loaʻa no ka Moʻo Hirschmann DRAGON MACH4000
DRAGON MACH4000-48G+4X-L2A
DRAGON MACH4000-48G+4X-L3A-UR
DRAGON MACH4000-48G+4X-L3A-MR
DRAGON MACH4000-52G-L2A
DRAGON MACH4000-52G-L3A-UR
DRAGON MACH4000-52G-L3A-MR
Nā huahana pili
-
Kuapo Hoʻokele Hirschmann RS20-0800T1T1SDAPHH
Wehewehe Huahana: Hirschmann RS20-0800T1T1SDAPHH Mea hoʻonohonoho: RS20-0800T1T1SDAPHH Wehewehe huahana Wehewehe Hoʻokele ʻia ka Fast-Ethernet-Switch no ka hoʻololi ʻana i ka hale kūʻai a me ka hoʻokele mua ʻana o ke kaʻaahi DIN, ka hoʻolālā ʻole fanless; Helu ʻĀpana ʻOihana Papa Hana 2 943434022 ʻAno puka a me ka nui 8 mau puka i ka huina: 6 x maʻamau 10/100 BASE TX, RJ45; Uplink 1: 1 x 10/100BASE-TX, RJ45; Uplink 2: 1 x 10/100BASE-TX, RJ45 Ambi...
-
Hoʻokele ʻia ʻo Hirschmann RS20-1600M2M2SDAE Compact ma...
Wehewehe huahana Wehewehe Hoʻokele ʻia ka Fast-Ethernet-Switch no ka hoʻololi ʻana i ka hale kūʻai a me ka hoʻokele mua ʻana o ke kaʻaahi DIN, ka hoʻolālā ʻole fanless; Helu ʻĀpana Hoʻonui ʻia o ka Papa Hana 2 943434005 ʻAno puka a me ka nui 16 mau puka i ka huina: 14 x maʻamau 10/100 BASE TX, RJ45; Uplink 1: 1 x 100BASE-FX, MM-SC; Uplink 2: 1 x 100BASE-FX, MM-SC Nā Interfaces Hou Aʻe ...
-
Mea Hoʻoili EEC Hirschmann M-SFP-LX/LC
Wehewehe huahana Wehewehe huahana ʻAno: M-SFP-LX+/LC EEC, SFP Transceiver Wehewehe: SFP Fiberoptic Gigabit Ethernet Transceiver SM, pae mahana i hoʻonui ʻia. Helu ʻāpana: 942024001 ʻAno awa a me ka nui: 1 x 1000 Mbit/s me ka mea hoʻohui LC Nui pūnaewele - ka lōʻihi o ke kaula Fiber ʻano hoʻokahi (SM) 9/125 µm: 14 - 42 km (Loulou Budget ma 1310 nm = 5 - 20 dB; A = 0,4 dB/km; D = 3,5 ps...
-
Hirschmann MM3-2FXM2/2TX1 Media module
Wehewehena Wehewehena huahana ʻAno: MM3-2FXM2/2TX1 Helu ʻĀpana: 943761101 ʻAno awa a me ka nui: 2 x 100BASE-FX, nā kaula MM, nā sockets SC, 2 x 10/100BASE-TX, nā kaula TP, nā sockets RJ45, auto-crossing, auto-negotiation, auto-polarity Nui o ka pūnaewele - ka lōʻihi o ke kaula Twisted pair (TP): 0-100 Multimode fiber (MM) 50/125 µm: 0 - 5000 m, 8 dB link budget ma 1300 nm, A = 1 dB/km, 3 dB reserve,...
-
ʻO Hirschmann SPIDER-PL-20-04T1M29999TWVHHHH Unman...
Wehewehe huahana Wehewehe ʻAʻole i mālama ʻia, Industrial ETHERNET Rail Switch, hoʻolālā fanless, mālama a me ke ʻano hoʻololi mua, interface USB no ka hoʻonohonoho ʻana, ʻano a me ka nui o ka Fast Ethernet Port 4 x 10/100BASE-TX, TP cable, RJ45 sockets, auto-crossing, auto-negotiation, auto-polarity, 1 x 100BASE-FX, MM cable, SC sockets Nā Interfaces Hou Aʻe ...
-
Hirschmann RS20-0800S2T1SDAU ʻOihana Hoʻokele ʻole ʻia...
Hoʻolauna ʻO nā kuapo Ethernet i mālama ʻole ʻia ʻo RS20/30 Hirschmann RS20-0800S2S2SDAUHC/HH Nā hiʻohiʻona i helu ʻia RS20-0800T1T1SDAUHC/HH RS20-0800M2M2SDAUHC/HH RS20-0800S2S2SDAUHC/HH RS20-1600M2M2SDAUHC/HH RS20-1600S2S2SDAUHC/HH RS30-0802O6O6SDAUHC/HH RS30-1602O6O6SDAUHC/HH RS20-0800S2T1SDAUHC RS20-1600T1T1SDAUHC RS20-2400T1T1SDAUHC