Phoenix Contact 2904601 QUINT4-PS/1AC/24DC/10 – ʻĀpana lako mana

Wehewehe Pōkole:

Hoʻokaʻaʻike Phoenix 2904601ʻO ka lako mana QUINT POWER i hoʻololi mua ʻia me ke koho manuahi o ke kiʻikuhi hiʻohiʻona hoʻopuka, ʻenehana SFB (selective fuse breaking), a me ka interface NFC, input: 1-phase, output: 24 V DC/10 A


Nā kikoʻī huahana

Nā Lepili Huahana

Ka wehewehe huahana

 

ʻO ka hanauna ʻehā o nā lako mana QUINT POWER hana kiʻekiʻe e hōʻoiaʻiʻo ana i ka loaʻa ʻana o ka ʻōnaehana maikaʻi loa ma o nā hana hou. Hiki ke hoʻoponopono pākahi ʻia nā paepae hōʻailona a me nā piʻo hiʻohiʻona ma o ka interface NFC.
ʻO ka ʻenehana SFB kūikawā a me ka nānā ʻana i ka hana pale o ka mana mana QUINT POWER e hoʻonui i ka loaʻa ʻana o kāu noi.

Lā Kūʻai

 

Helu mea 2904601
ʻĀpana hoʻopili 1 ʻāpana
Kī kūʻai aku CM10
Kī huahana CMPI13
ʻAoʻao papa inoa ʻAoʻao 235 (C-4-2019)
GTIN 4046356985338
Kaumaha no kēlā me kēia ʻāpana (me ka hoʻopili ʻana) 1,150 g
Kaumaha no kēlā me kēia ʻāpana (koe naʻe ka hoʻopili ʻana) 869 g
Helu ʻauhau dute 85044095
ʻĀina kumu TH

Kou mau pono

 

Hoʻopau koho ka ʻenehana SFB i nā mea haki kaapuni maʻamau, e hoʻomau ka hana ʻana o nā ukana i hoʻopili ʻia ma ke ʻano like

Hōʻike ka nānā ʻana i ka hana pale i nā kūlana hana koʻikoʻi ma mua o ka hiki ʻana mai o nā hewa

ʻO nā paepae hōʻailona a me nā piʻo hiʻohiʻona hiki ke hoʻoponopono ʻia ma o NFC e hoʻonui i ka loaʻa ʻana o ka ʻōnaehana

Hoʻonui maʻalahi i ka ʻōnaehana mahalo i ka hoʻoikaika static; hoʻomaka o nā ukana paʻakikī mahalo i ka hoʻoikaika dynamic

Ke kiʻekiʻe o ka palekana, mahalo i ka mea hoʻopaʻa pale i hoʻopiha ʻia me ke kinoea a me ka manawa hoʻopili hemahema mains o 20 milliseconds.

Hoʻolālā paʻa mahalo i ka hale metala a me ka laulā o ka mahana mai -40°C a i +70°C

Hoʻohana ʻia ma ka honua holoʻokoʻa mahalo i ka laulā o ka hoʻokomo ʻana a me ka pūʻolo ʻae honua

Nā ʻāpana lako mana Phoenix Contact

 

E hoʻolako pono i kāu noi me kā mākou mau lako mana. E koho i ka lako mana kūpono e kūpono i kāu mau pono mai kā mākou ʻano huahana like ʻole. ʻOkoʻa nā ʻāpana lako mana DIN rail e pili ana i kā lākou hoʻolālā, mana, a me ka hana. Ua hoʻopilikino maikaʻi ʻia lākou i nā koi o nā ʻoihana like ʻole, me ka ʻoihana kaʻa, ke kūkulu mīkini, ka ʻenehana hana, a me ke kūkulu moku.

Nā lako mana Phoenix Contact me ka hana nui loa

 

Hāʻawi nā lako mana QUINT POWER ikaika me ka hana kiʻekiʻe loa i ka loaʻa ʻana o ka ʻōnaehana maikaʻi loa mahalo i ka ʻenehana SFB a me ka hoʻonohonoho pilikino o nā paepae hōʻailona a me nā piʻo hiʻohiʻona. Loaʻa i nā lako mana QUINT POWER ma lalo o 100 W ka hui kūikawā o ka nānā ʻana i ka hana pale a me ka mālama mana ikaika i kahi nui liʻiliʻi.


  • Ma mua:
  • Aʻe:

  • E kākau i kāu leka ma aneʻi a hoʻouna mai iā mākou

    Nā huahana pili

    • Phoenix Contact 2866776 QUINT-PS/1AC/24DC/20 - ʻĀpana hoʻolako mana

      Phoenix Contact 2866776 QUINT-PS/1AC/24DC/20 - ...

      Lā Kūʻai Helu mea 2866776 ʻĀpana hoʻopili 1 pc Ka nui o ke kauoha liʻiliʻi loa 1 pc Kī kūʻai CMPQ13 Kī huahana CMPQ13 ʻAoʻao papa inoa ʻAoʻao 159 (C-6-2015) GTIN 4046356113557 Kaumaha no kēlā me kēia ʻāpana (me ka hoʻopili ʻana) 2,190 g Kaumaha no kēlā me kēia ʻāpana (koe naʻe ka hoʻopili ʻana) 1,608 g Helu ʻauhau dute 85044095 ʻĀina kumu TH Wehewehe huahana QUINT...

    • ʻO ka poloka kikowaena hānai Phoenix Contact 3031212 ST 2,5

      Phoenix Contact 3031212 ST 2,5 Feed-through Ter...

      Lā Kūʻai Helu mea 3031212 ʻĀpana hoʻopili 50 pc Ka nui o ke kauoha liʻiliʻi loa 50 pc Kī kūʻai BE2111 Kī huahana BE2111 GTIN 4017918186722 Kaumaha no kēlā me kēia ʻāpana (me ka hoʻopili ʻana) 6.128 g Kaumaha no kēlā me kēia ʻāpana (koe naʻe ka hoʻopili ʻana) 6.128 g Helu ʻauhau dute 85369010 ʻĀina i hana ʻia DE LĀ ʻenehana ʻAno huahana Poloka terminal hānai ʻOhana huahana ST Wahi o...

    • ʻO ka Phoenix Contact TB 4-HESILED 24 (5X20) I 3246434 Fuse Terminal Block

      ʻO Phoenix Contact TB 4-HESILED 24 (5X20) I 324643...

      Lā Kūʻai Helu Kauoha 3246434 ʻĀpana hoʻopili 50 pc Ka nui o ke kauoha liʻiliʻi loa 50 pc Kōkuhi kī kūʻai BEK234 Kōkuhi kī huahana BEK234 GTIN 4046356608626 Kaumaha no kēlā me kēia ʻāpana (me ka hoʻopili ʻana) 13.468 g Kaumaha no kēlā me kēia ʻāpana (koe naʻe ka hoʻopili ʻana) 11.847 g ʻāina kumu CN LĀ ʻENEHANA laulā 8.2 mm kiʻekiʻe 58 mm NS 32 Hohonu 53 mm NS 35/7,5 hohonu 48 mm ...

    • ʻO ka poloka kikowaena hānai Phoenix Contact UT 16 3044199

      Phoenix Contact UT 16 3044199 Kau Hānai-ma o...

      Lā Kūʻai Helu mea 3044199 ʻĀpana hoʻopili 50 pc Ka nui o ke kauoha liʻiliʻi loa 1 pc Kī huahana BE1111 GTIN 4017918977535 Kaumaha no kēlā me kēia ʻāpana (me ka hoʻopili ʻana) 29.803 g Kaumaha no kēlā me kēia ʻāpana (koe naʻe ka hoʻopili ʻana) 30.273 g Helu ʻauhau dute 85369010 ʻĀina kumu TR LĀ ʻenehana Helu o nā pilina no kēlā me kēia pae 2 ʻĀpana kea inoa 16 mm² Pae 1 ma luna ...

    • Phoenix Contact 2903144 TRIO-PS-2G/1AC/24DC/5/B+D - ʻĀpana hoʻolako mana

      Phoenix Contact 2903144 TRIO-PS-2G/1AC/24DC/5/B...

      ʻO ka wehewehe huahana nā lako mana QUINT POWER me ka hana nui loa QUINT POWER circuit breakers magneticly a no laila e holo wikiwiki i ʻeono manawa o ke au i manaʻo ʻia, no ka pale ʻōnaehana koho a no laila e uku pono ai. Ua hōʻoia ʻia ke kiʻekiʻe o ka loaʻa ʻana o ka ʻōnaehana, mahalo i ka nānā ʻana i ka hana pale, no ka mea e hōʻike ana i nā kūlana hana koʻikoʻi ma mua o ka hiki ʻana mai o nā hewa. Hoʻomaka hilinaʻi o nā ukana kaumaha ...

    • ʻO ka poloka terminal hānai Phoenix Contact 3209510

      Phoenix Contact 3209510 Feed-through terminal b ...

      Lā Kūʻai Helu mea 3209510 ʻĀpana hoʻopili 50 pc Ka nui o ke kauoha liʻiliʻi loa 50 pc Kī kūʻai BE02 Kī huahana BE2211 ʻAoʻao papa inoa ʻAoʻao 71 (C-1-2019) GTIN 4046356329781 Kaumaha no kēlā me kēia ʻāpana (me ka hoʻopili ʻana) 6.35 g Kaumaha no kēlā me kēia ʻāpana (koe naʻe ka hoʻopili ʻana) 5.8 g Helu ʻauhau dute 85369010 ʻĀina i hana ʻia DE LĀ ʻenehana ʻAno huahana Poloka terminal hānai ...