• poʻo_hae_01

MOXA EDS-G308 8G-port Full Gigabit Unmanaged Industrial Ethernet Switch

Wehewehe Pōkole:

Ua lako nā kuapo EDS-G308 me 8 mau awa Gigabit Ethernet a me 2 mau awa fiber-optic, e kūpono ana iā lākou no nā noi e koi ana i ka bandwidth kiʻekiʻe. Hāʻawi nā kuapo EDS-G308 i kahi hopena hoʻokele waiwai no kāu mau pilina Gigabit Ethernet ʻoihana, a ʻo ka hana hōʻike relay i kūkulu ʻia e hoʻomaopopo i nā luna hoʻokele pūnaewele ke hāʻule ka mana a i ʻole ka haki ʻana o ka awa. Hiki ke hoʻohana ʻia nā kuapo DIP 4-pin no ka kaohi ʻana i ka pale hoʻolaha, nā kiʻi jumbo, a me ka mālama ikehu IEEE 802.3az. Eia kekahi, kūpono ka hoʻololi wikiwiki 100/1000 SFP no ka hoʻonohonoho maʻalahi ma ka pūnaewele no kekahi noi automation ʻoihana.

Loaʻa kahi kumu hoʻohālike mahana maʻamau, nona ka pae mahana hana o -10 a 60°C, a me kahi kumu hoʻohālike ākea ākea, nona ka pae mahana hana o -40 a 75°C. Loaʻa nā kumu hoʻohālike ʻelua i kahi hoʻāʻo puhi-i loko 100% e hōʻoia i ko lākou hoʻokō ʻana i nā pono kūikawā o nā noi hoʻokele automation ʻoihana. Hiki ke hoʻokomo maʻalahi ʻia nā kuapo ma kahi DIN rail a i ʻole i loko o nā pahu hāʻawi.


Nā kikoʻī huahana

Nā Lepili Huahana

Nā Hiʻohiʻona a me nā Pōmaikaʻi

Nā koho fiber-optic no ka hoʻolōʻihi ʻana i ka mamao a me ka hoʻomaikaʻi ʻana i ka pale ʻana i ka walaʻau uila Nā mea hoʻokomo mana VDC pālua 12/24/48

Kākoʻo i nā mōlina jumbo 9.6 KB

ʻŌlelo aʻo hoʻopuka relay no ka hāʻule ʻana o ka mana a me ka alarm haki awa

Ka palekana ʻino hoʻolaha

-40 a i 75°C ka pae mahana hana (nā kumu hoʻohālike-T)

Nā kikoʻī

ʻO ka pilina hoʻokomo/hoʻopuka

Nā Kanal Hoʻokaʻaʻike Alarm 1 hoʻopuka relay me ka mana lawe o kēia manawa o 1 A @ 24 VDC

ʻO ka pilina Ethernet

Nā awa 10/100/1000BaseT(X) (mea hoʻohui RJ45) EDS-G308/G308-T: 8EDS-G308-2SFP/G308-2SFP-T: 6Kākoʻo nā ʻano hoʻohālike āpau:

Ka wikiwiki o ke kūkākūkā aunoa

ʻAno duplex piha/hapa

Hoʻohui MDI/MDI-X aunoa

Nā awa hui (10/100/1000BaseT(X) a i ʻole 100/1000BaseSFP+) EDS-G308-2SFP: 2EDS-G308-2SFP-T: 2
Nā Kūlana ʻO IEEE 802.3 no 10BaseTIEEE 802.3ab no 1000BaseT(X)IEEE 802.3u no 100BaseT(X) a me 100BaseFX

ʻO IEEE 802.3x no ka kaohi ʻana i ke kahe

IEEE 802.3z no 1000BaseX

ʻO IEEE 802.3az no ka Ethernet Hoʻohana Ikehu

Nā Palena Mana

Hoʻohui 1 poloka kikowaena 6-pili hiki ke wehe ʻia
Anakahi Hoʻokomo 12/24/48 VDC, Nā hoʻokomo pālua Redundant
Anakahi Hana 9.6 a i 60 VDC
Ka Palekana Polarity Hoʻohuli Kākoʻo ʻia
Ke hoʻokomo nei i kēia manawa EDS-G308: 0.29 A@24 VDCEDS-G308-2SFP: 0.31 A@24 VDC

Nā ʻano kino

Hale noho Metala
Ka helu IP IP30
Nā Ana 52.85 x135x105 mm (2.08 x 5.31 x 4.13 ʻīniha)
Kaumaha 880 g (1.94 lb)
Hoʻokomo ʻana Ke kau ʻana o ke alahao DIN, Ke kau ʻana ma ka paia (me ka pahu koho)

Nā Palena Kaiapuni

Mahana Hana Nā Kumu Hoʻohālike Maʻamau: -10 a 60°C (14 a 140°F) Nā Kumu Hoʻohālike Mahana Laulā: -40 a 75°C (-40 a 167°F)
Ka Mahana Mālama (ua hoʻokomo ʻia ka pūʻolo) -40 a i 85°C (-40 a i 185°F)
Ka Haumākū Pili Ambient 5 a 95% (ʻaʻole e hoʻopili ʻia)

Nā Kumu Hoʻohālike i Loaʻa iā MOXA EDS-308

Kumu Hoʻohālike 1 MOXA EDS-G308
Kumu Hoʻohālike 2 MOXA EDS-G308-T
Kumu Hoʻohālike 3 MOXA EDS-G308-2SFP
Kumu Hoʻohālike 4 MOXA EDS-G308-2SFP-T

  • Ma mua:
  • Aʻe:

  • E kākau i kāu leka ma aneʻi a hoʻouna mai iā mākou

    Nā huahana pili

    • Module SFP Ethernet Gigabit 1-awa MOXA SFP-1GSXLC-T

      MOXA SFP-1GSXLC-T 1-awa Gigabit Ethernet SFP M...

      Nā Hiʻohiʻona a me nā Pōmaikaʻi Hana Nānā Diagnostic Digital -40 a 85°C ka laulā mahana hana (nā kumu hoʻohālike T) IEEE 802.3z kūlike Nā mea hoʻokomo a me nā hopena LVPECL ʻokoʻa Hōʻailona ʻike hōʻailona TTL Hoʻohui duplex LC pluggable wela Huahana laser papa 1, kūlike me EN 60825-1 Nā Palena Mana Hoʻohana Mana Max. 1 W ...

    • Mea Hoʻololi Serial-to-Fiber MOXA ICF-1150I-M-SC

      Mea Hoʻololi Serial-to-Fiber MOXA ICF-1150I-M-SC

      Nā Hiʻohiʻona a me nā Pōmaikaʻi Kamaʻilio 3-ala: RS-232, RS-422/485, a me ka fiber Rotary switch e hoʻololi i ka waiwai resistor kiʻekiʻe/haʻahaʻa huki Hoʻonui i ka hoʻoili RS-232/422/485 a hiki i 40 km me ke ʻano hoʻokahi a i ʻole 5 km me ka multi-mode -40 a 85°C ākea-wela nā hiʻohiʻona i loaʻa C1D2, ATEX, a me IECEx i hōʻoia ʻia no nā ʻano ʻoihana ʻino Nā kikoʻī ...

    • ʻO MOXA MGate MB3170I Modbus TCP Gateway

      ʻO MOXA MGate MB3170I Modbus TCP Gateway

      Nā Hiʻohiʻona a me nā Pōmaikaʻi Kākoʻo i ke Alanui Hana Auto no ka hoʻonohonoho maʻalahi Kākoʻo i ke ala ma o ka puka TCP a i ʻole ka helu IP no ka hoʻolaha maʻalahi Hoʻohui a hiki i 32 mau kikowaena Modbus TCP Hoʻohui a hiki i 31 a i ʻole 62 mau kauā Modbus RTU/ASCII Loaʻa i nā mea kūʻai aku Modbus TCP a hiki i 32 (mālama i 32 mau noi Modbus no kēlā me kēia Master) Kākoʻo i nā kamaʻilio kauā serial Modbus i nā kamaʻilio kauā serial Modbus Ethernet i kūkulu ʻia no ka wir maʻalahi ...

    • Nā Puka Kelepona MOXA OnCell G3150A-LTE-EU

      Nā Puka Kelepona MOXA OnCell G3150A-LTE-EU

      Hoʻolauna ʻO ka OnCell G3150A-LTE kahi puka LTE hilinaʻi a palekana me ka uhi LTE honua kiʻekiʻe loa. Hāʻawi kēia puka kelepona LTE i kahi pilina hilinaʻi i kāu mau pūnaewele serial a me Ethernet no nā noi kelepona. No ka hoʻonui ʻana i ka hilinaʻi ʻoihana, hōʻike ka OnCell G3150A-LTE i nā mea hoʻokomo mana i hoʻokaʻawale ʻia, kahi e hui pū ai me ke kākoʻo EMS kiʻekiʻe a me ka mahana ākea e hāʻawi i ka OnCell G3150A-LT...

    • Mea Hoʻololi Serial-to-Fiber ʻOihana MOXA TCF-142-M-ST-T

      MOXA TCF-142-M-ST-T Hanalima Serial-to-Fiber ...

      Nā Hiʻohiʻona a me nā Pōmaikaʻi Hoʻoili apo a me ke kiko-a-kiko Hoʻonui i ka hoʻoili RS-232/422/485 a hiki i 40 km me ke ʻano hoʻokahi (TCF-142-S) a i ʻole 5 km me ke ʻano multi-mode (TCF-142-M) Hoʻemi i ka hoʻopilikia hōʻailona Pale aku i ka hoʻopilikia uila a me ka pala kemika Kākoʻo i nā baudrates a hiki i 921.6 kbps Loaʻa nā hiʻohiʻona wela ākea no nā wahi -40 a 75°C ...

    • MOXA EDS-510E-3GTXSFP Papa 2 Hoʻokele ʻia ka Ethernet ʻoihana kuapo

      ʻOihana Hoʻokele ʻia ʻo MOXA EDS-510E-3GTXSFP Papa 2...

      Nā Hiʻohiʻona a me nā Pōmaikaʻi 3 mau awa Gigabit Ethernet no nā apo redundant a i ʻole nā ​​​​​​hoʻonā uplinkTurbo Ring a me Turbo Chain (manawa hoʻōla <20 ms @ 250 mau kuapo), RSTP/STP, a me MSTP no ka redundancy pūnaeweleRADIUS, TACACS+, SNMPv3, IEEE 802.1x, HTTPS, SSH, a me ka helu wahi MAC sticky e hoʻonui i ka palekana pūnaeweleNā hiʻohiʻona palekana e pili ana i nā protocols IEC 62443 EtherNet/IP, PROFINET, a me Modbus TCP i kākoʻo ʻia no ka hoʻokele hāmeʻa a me...