MOXA ICS-G7850A-2XG-HV-HV 48G+2 10GbE Papa 3 Gigabit Piha Modular Hoʻokele ʻOihana Ethernet Kuapo
A hiki i 48 mau awa Gigabit Ethernet a me 2 mau awa Ethernet 10G
A hiki i 50 mau pilina fiber optical (nā kau SFP)
A hiki i 48 mau awa PoE+ me ka lako mana waho (me ka module IM-G7000A-4PoE)
ʻAʻohe Fanless, -10 a 60°C ka laulā mahana hana
Hoʻolālā modular no ka maʻalahi loa a me ka hoʻonui ʻana i ka wā e hiki mai ana me ka pilikia ʻole
ʻO ka ʻaoʻao hoʻololi wela a me nā modula mana no ka hana mau
ʻO ke apo Turbo a me ke kaulahao Turbo (manawa hoʻōla <20 ms @ 250 mau kuapo), a me STP/RSTP/MSTP no ka redundancy pūnaewele
Nā mea hoʻokomo mana keu i hoʻokaʻawale ʻia me ka laulā lako mana 110/220 VAC ākea
Kākoʻo iā MXstudio no ka hoʻokele pūnaewele ʻoihana maʻalahi a ʻike maka ʻia
Hoʻomaopopo ʻo V-ON™ i ka hoʻōla ʻana o ka ʻikepili multicast pae millisecond a me ka pūnaewele wikiō
Hana hoʻololi Layer 3 e hoʻoneʻe i ka ʻikepili a me ka ʻike ma waena o nā pūnaewele (ICS-G7800A Series)
Nā hana hoʻokele PoE holomua: hoʻonohonoho hoʻopuka PoE, nānā hemahema PD, hoʻonohonoho PoE, a me nā diagnostics PoE (me ka module IM-G7000A-4PoE)
ʻO ka ʻaoʻao laina kauoha (CLI) no ka hoʻonohonoho wikiwiki ʻana i nā hana nui i mālama ʻia
Kākoʻo i ka hiki VLAN holomua me ka hōʻailona Q-in-Q
Koho DHCP 82 no ka hoʻokaʻawale ʻana i ka helu wahi IP me nā kulekele like ʻole
Kākoʻo i nā protocols EtherNet/IP a me Modbus TCP no ka hoʻokele hāmeʻa a me ka nānā ʻana
Kūlike me ke kaʻina hana PROFINET no ka hoʻoili ʻikepili moakāka
Nā hoʻokomo kikohoʻe no ka hoʻohui ʻana i nā mea ʻike a me nā alarm me nā pūnaewele IP
Nā mea hoʻokomo mana AC pālua, redundant
Ka nānā ʻana iā IGMP a me GMRP no ka kānana ʻana i ke kaʻa multicast
ʻO IEEE 802.1Q VLAN a me GVRP protocol e hoʻomaʻalahi i ka hoʻolālā pūnaewele
ʻO QoS (IEEE 802.1p/1Q a me TOS/DiffServ) e hoʻonui i ka determinism
ʻO Port Trunking no ka hoʻohana ʻana i ka bandwidth kūpono loa
ʻO TACACS+, SNMPv3, IEEE 802.1X, HTTPS, a me SSH e hoʻoikaika i ka palekana pūnaewele
Hoʻonui nā papa inoa kaohi komo (ACL) i ka maʻalahi a me ka palekana o ka hoʻokele pūnaewele
SNMPv1/v2c/v3 no nā pae like ʻole o ka hoʻokele pūnaewele
RMON no ka nānā ʻana i ka pūnaewele proactive a me ka pono
Ka hoʻokele bandwidth e pale aku i ke kūlana pūnaewele hiki ʻole ke wānana ʻia
Hana laka puka no ka pale ʻana i ke komo ʻae ʻole ʻia ma muli o ka helu wahi MAC
Ke aniani ʻana o ke awa no ka debugging pūnaewele
ʻŌlelo aʻo akomi ma o ka ʻokoʻa ma o ka leka uila a me ka hoʻopuka relay
| Nā Kanal Hoʻokaʻaʻike Alarm | Ka hoʻopuka relay me ka mana lawe o kēia manawa o 2A @ 30 VDC |
| Nā Hoʻokomo Kikohoʻe | +13 a i +30 V no ke kūlana 1 -30 a i +1 V no ke kūlana 0 Ka nui o ke au hoʻokomo: 8 mA |
| 10GbESFP+Nā Māhele | 2 |
| Hoʻohuihui Slot | 12 mau kau no nā modula interface 4-port (10/100/1000BaseT(X), a i ʻole PoE+ 10/100/1000BaseT (X), a i ʻole 100/1000BaseSFP mau kau)2 |
| Nā Kūlana | ʻO IEEE 802.1D-2004 no ka Spanning Tree ProtocolIEEE 802.1p no ka Papa HanaIEEE 802.1Q no ka VLAN TaggingIEEE 802.1s no ka Multiple Spanning Tree ProtocolIEEE 802.1w no ka Rapid Spanning Tree Protocol IEEE 802.1X no ka hōʻoia ʻana IEEE 802.3 no 10BaseT ʻO IEEE 802.3ab no 1000BaseT(X) ʻO IEEE 802.3ad no Port Trunk me LACP ʻO IEEE 802.3u no 100BaseT(X) a me 100BaseFX ʻO IEEE 802.3x no ka kaohi ʻana i ke kahe ʻO IEEE 802.3z no 1000BaseSX/LX/LHX/ZX ʻO IEEE 802.3af/at no ka hoʻopuka PoE/PoE+ ʻO IEEE 802.3ae no 10 Gigabit Ethernet |
| Anakahi Hoʻokomo | 110 a 220 VAC, Nā hoʻokomo pālua Redundant |
| Anakahi Hana | 85 a i 264 VAC |
| Ka Palekana o ke Au Loa | Kākoʻo ʻia |
| Ka Palekana Polarity Hoʻohuli | Kākoʻo ʻia |
| Ke hoʻokomo nei i kēia manawa | 0.94/0.55 A@ 110/220 VAC |
| Ka helu IP | IP30 |
| Nā Ana | 440 x176x 523.8 mm (17.32 x 6.93 x 20.62 ʻīniha) |
| Kaumaha | 12900 g (28.5 lb) |
| Hoʻokomo ʻana | Ke kau ʻana o ka pā |
| Mahana Hana | -10 a i 60°C (14 a i 140°F) |
| Ka Mahana Mālama (ua hoʻokomo ʻia ka pūʻolo) | -40 a i 85°C (-40 a i 185°F) |
| Ka Haumākū Pili Ambient | 5 a 95% (ʻaʻole e hoʻopili ʻia) |