• poʻo_hae_01

MOXA ICS-G7850A-2XG-HV-HV 48G+2 10GbE Papa 3 Gigabit Piha Modular Hoʻokele ʻOihana Ethernet Kuapo

Wehewehe Pōkole:

Hoʻohui nā noi automation kaʻina hana a me ka automation halihali i ka ʻikepili, leo, a me ke wikiō, a no laila e koi ana i ka hana kiʻekiʻe a me ka hilinaʻi kiʻekiʻe. ʻO ka hoʻolālā modular o nā kuapo backbone Gigabit piha o ICS-G7850A Series e maʻalahi ai ka hoʻolālā pūnaewele, a hiki ke ʻae i ka maʻalahi nui aʻe ma ka ʻae ʻana iā ʻoe e hoʻokomo a hiki i 48 mau awa Gigabit Ethernet a me 2 10 mau awa Gigabit Ethernet.

Kākoʻo nā kuapo fanless i nā ʻenehana Turbo Ring, Turbo Chain, a me RSTP/STP redundancy, a hele mai me kahi lako mana redundant i hoʻokaʻawale ʻia e hoʻonui i ka hilinaʻi o ka ʻōnaehana a me ka loaʻa ʻana o kāu iwi kuamoʻo pūnaewele.


Nā kikoʻī huahana

Nā Lepili Huahana

Nā Hiʻohiʻona a me nā Pōmaikaʻi

A hiki i 48 mau awa Gigabit Ethernet a me 2 mau awa Ethernet 10G
A hiki i 50 mau pilina fiber optical (nā kau SFP)
A hiki i 48 mau awa PoE+ me ka lako mana waho (me ka module IM-G7000A-4PoE)
ʻAʻohe Fanless, -10 a 60°C ka laulā mahana hana
Hoʻolālā modular no ka maʻalahi loa a me ka hoʻonui ʻana i ka wā e hiki mai ana me ka pilikia ʻole
ʻO ka ʻaoʻao hoʻololi wela a me nā modula mana no ka hana mau
ʻO ke apo Turbo a me ke kaulahao Turbo (manawa hoʻōla <20 ms @ 250 mau kuapo), a me STP/RSTP/MSTP no ka redundancy pūnaewele
Nā mea hoʻokomo mana keu i hoʻokaʻawale ʻia me ka laulā lako mana 110/220 VAC ākea
Kākoʻo iā MXstudio no ka hoʻokele pūnaewele ʻoihana maʻalahi a ʻike maka ʻia
Hoʻomaopopo ʻo V-ON™ i ka hoʻōla ʻana o ka ʻikepili multicast pae millisecond a me ka pūnaewele wikiō

Nā Hiʻohiʻona a me nā Pōmaikaʻi ʻē aʻe

Hana hoʻololi Layer 3 e hoʻoneʻe i ka ʻikepili a me ka ʻike ma waena o nā pūnaewele (ICS-G7800A Series)
Nā hana hoʻokele PoE holomua: hoʻonohonoho hoʻopuka PoE, nānā hemahema PD, hoʻonohonoho PoE, a me nā diagnostics PoE (me ka module IM-G7000A-4PoE)
ʻO ka ʻaoʻao laina kauoha (CLI) no ka hoʻonohonoho wikiwiki ʻana i nā hana nui i mālama ʻia
Kākoʻo i ka hiki VLAN holomua me ka hōʻailona Q-in-Q
Koho DHCP 82 no ka hoʻokaʻawale ʻana i ka helu wahi IP me nā kulekele like ʻole
Kākoʻo i nā protocols EtherNet/IP a me Modbus TCP no ka hoʻokele hāmeʻa a me ka nānā ʻana
Kūlike me ke kaʻina hana PROFINET no ka hoʻoili ʻikepili moakāka
Nā hoʻokomo kikohoʻe no ka hoʻohui ʻana i nā mea ʻike a me nā alarm me nā pūnaewele IP
Nā mea hoʻokomo mana AC pālua, redundant
Ka nānā ʻana iā IGMP a me GMRP no ka kānana ʻana i ke kaʻa multicast
ʻO IEEE 802.1Q VLAN a me GVRP protocol e hoʻomaʻalahi i ka hoʻolālā pūnaewele
ʻO QoS (IEEE 802.1p/1Q a me TOS/DiffServ) e hoʻonui i ka determinism
ʻO Port Trunking no ka hoʻohana ʻana i ka bandwidth kūpono loa
ʻO TACACS+, SNMPv3, IEEE 802.1X, HTTPS, a me SSH e hoʻoikaika i ka palekana pūnaewele
Hoʻonui nā papa inoa mana komo (ACL) i ka maʻalahi a me ka palekana o ka hoʻokele pūnaewele
SNMPv1/v2c/v3 no nā pae like ʻole o ka hoʻokele pūnaewele
RMON no ka nānā ʻana i ka pūnaewele proactive a me ka pono
Ka hoʻokele bandwidth e pale aku i ke kūlana pūnaewele hiki ʻole ke wānana ʻia
Hana laka puka no ka pale ʻana i ke komo ʻae ʻole ʻia ma muli o ka helu wahi MAC
Ke aniani ʻana o ke awa no ka debugging pūnaewele
ʻŌlelo aʻo akomi ma o ka ʻokoʻa ma o ka leka uila a me ka hoʻopuka relay

ʻO ka pilina hoʻokomo/hoʻopuka

Nā Kanal Hoʻokaʻaʻike Alarm Ka hoʻopuka relay me ka mana lawe o kēia manawa o 2A @ 30 VDC
Nā Hoʻokomo Kikohoʻe +13 a i +30 V no ke kūlana 1 -30 a i +1 V no ke kūlana 0 Ka nui o ke au hoʻokomo: 8 mA

ʻO ka pilina Ethernet

10GbESFP+Nā Māhele 2
Hoʻohuihui Slot 12 mau kau no nā modula interface 4-port (10/100/1000BaseT(X), a i ʻole PoE+ 10/100/1000BaseT (X), a i ʻole 100/1000BaseSFP mau kau)2
Nā Kūlana ʻO IEEE 802.1D-2004 no ka Spanning Tree ProtocolIEEE 802.1p no ka Papa HanaIEEE 802.1Q no ka VLAN TaggingIEEE 802.1s no ka Multiple Spanning Tree ProtocolIEEE 802.1w no ka Rapid Spanning Tree Protocol

IEEE 802.1X no ka hōʻoia ʻana

IEEE 802.3 no 10BaseT

ʻO IEEE 802.3ab no 1000BaseT(X)

ʻO IEEE 802.3ad no Port Trunk me LACP

ʻO IEEE 802.3u no 100BaseT(X) a me 100BaseFX

ʻO IEEE 802.3x no ka kaohi ʻana i ke kahe

ʻO IEEE 802.3z no 1000BaseSX/LX/LHX/ZX

ʻO IEEE 802.3af/at no ka hoʻopuka PoE/PoE+

ʻO IEEE 802.3ae no 10 Gigabit Ethernet

Nā Palena Mana

Anakahi Hoʻokomo 110 a 220 VAC, Nā hoʻokomo pālua Redundant
Anakahi Hana 85 a i 264 VAC
Ka Palekana o ke Au Loa Kākoʻo ʻia
Ka Palekana Polarity Hoʻohuli Kākoʻo ʻia
Ke hoʻokomo nei i kēia manawa 0.94/0.55 A@ 110/220 VAC

Nā ʻano kino

Ka helu IP IP30
Nā Ana 440 x176x 523.8 mm (17.32 x 6.93 x 20.62 ʻīniha)
Kaumaha 12900 g (28.5 lb)
Hoʻokomo ʻana Ke kau ʻana o ka pā

Nā Palena Kaiapuni

Mahana Hana -10 a i 60°C (14 a i 140°F)
Ka Mahana Mālama (ua hoʻokomo ʻia ka pūʻolo) -40 a i 85°C (-40 a i 185°F)
Ka Haumākū Pili Ambient 5 a 95% (ʻaʻole e hoʻopili ʻia)

  • Ma mua:
  • Aʻe:

  • E kākau i kāu leka ma aneʻi a hoʻouna mai iā mākou

    Nā huahana pili

    • MOXA EDS-G308-2SFP 8G-port Full Gigabit Unmanaged Industrial Ethernet Switch

      MOXA EDS-G308-2SFP 8G-port Full Gigabit Unmanag...

      Nā Hiʻohiʻona a me nā Pōmaikaʻi Nā koho fiber-optic no ka hoʻolōʻihi ʻana i ka mamao a me ka hoʻomaikaʻi ʻana i ka pale ʻana i ka walaʻau uila Nā mea hoʻokomo mana 12/24/48 VDC pālua ʻelua Kākoʻo i nā kiʻi jumbo 9.6 KB Hōʻike hoʻopuka relay no ka hāʻule ʻana o ka mana a me ka alarm haki port Palekana ʻino hoʻolaha -40 a 75°C pae mahana hana (-T mau hiʻohiʻona) Nā kikoʻī ...

    • Kikowaena Hana Serial Rackmount ʻOihana MOXA NPort 5650-16

      MOXA NPort 5650-16 ʻOihana Rackmount Serial ...

      Nā Hiʻohiʻona a me nā Pōmaikaʻi Ka nui o ka rackmount maʻamau 19-'īniha Ka hoʻonohonoho maʻalahi o ka helu wahi IP me ka panela LCD (koe naʻe nā hiʻohiʻona wela ākea) E hoʻonohonoho ʻia e Telnet, polokalamu kele pūnaewele, a i ʻole ka pono Windows Nā ʻano socket: kikowaena TCP, mea kūʻai aku TCP, UDP SNMP MIB-II no ka hoʻokele pūnaewele Ka laulā voltage kiʻekiʻe honua: 100 a 240 VAC a i ʻole 88 a 300 VDC Nā laulā voltage haʻahaʻa kaulana: ±48 VDC (20 a 72 VDC, -20 a -72 VDC) ...

    • ʻO ka Module SFP Ethernet Gigabit 1-port MOXA SFP-1GSXLC-T

      MOXA SFP-1GSXLC-T 1-awa Gigabit Ethernet SFP M...

      Nā Hiʻohiʻona a me nā Pōmaikaʻi Hana Nānā Diagnostic Digital -40 a 85°C ka laulā mahana hana (nā kumu hoʻohālike T) IEEE 802.3z kūlike Nā mea hoʻokomo a me nā hopena LVPECL ʻokoʻa Hōʻailona ʻike hōʻailona TTL Hoʻohui duplex LC pluggable wela Huahana laser papa 1, kūlike me EN 60825-1 Nā Palena Mana Hoʻohana Mana Max. 1 W ...

    • Kikowaena Hana Serial Rackmount ʻOihana MOXA NPort 5610-16

      MOXA NPort 5610-16 ʻOihana Rackmount Serial ...

      Nā Hiʻohiʻona a me nā Pōmaikaʻi Ka nui o ka rackmount maʻamau 19-'īniha Ka hoʻonohonoho maʻalahi o ka helu wahi IP me ka panela LCD (koe naʻe nā hiʻohiʻona wela ākea) E hoʻonohonoho ʻia e Telnet, polokalamu kele pūnaewele, a i ʻole ka pono Windows Nā ʻano socket: kikowaena TCP, mea kūʻai aku TCP, UDP SNMP MIB-II no ka hoʻokele pūnaewele Ka laulā voltage kiʻekiʻe honua: 100 a 240 VAC a i ʻole 88 a 300 VDC Nā laulā voltage haʻahaʻa kaulana: ±48 VDC (20 a 72 VDC, -20 a -72 VDC) ...

    • Hoʻohui MOXA TB-F25

      Hoʻohui MOXA TB-F25

      ʻO nā kaula a Moxa Loaʻa nā kaula a Moxa i nā ʻano lōʻihi like ʻole me nā koho pine he nui e hōʻoia i ka hoʻohālikelike ʻana no nā ʻano noi like ʻole. Hoʻokomo pū nā mea hoʻohui a Moxa i kahi koho o nā ʻano pine a me nā code me nā helu IP kiʻekiʻe e hōʻoia i ke kūpono no nā wahi ʻoihana. Nā kikoʻī Nā ʻano kino Wehewehe TB-M9: DB9 ...

    • MOXA ioLogik E1240 Nā Mana Hoʻokele Universal Ethernet Remote I/O

      MOXA ioLogik E1240 Nā Mana Hoʻokele Universal Ethern...

      Nā Hiʻohiʻona a me nā Pōmaikaʻi Hoʻokaʻaʻike Kauā Modbus TCP hiki ke wehewehe ʻia e ka mea hoʻohana Kākoʻo i ka RESTful API no nā noi IIoT Kākoʻo i ka EtherNet/IP Adapter Hoʻololi Ethernet 2-port no nā topologies daisy-chain Mālama i ka manawa a me nā kumukūʻai uea me nā kamaʻilio peer-to-peer Kamaʻilio ikaika me ka MX-AOPC UA Server Kākoʻo i ka SNMP v1/v2c Hoʻolaha maʻalahi a me ka hoʻonohonoho ʻana me ka pono ioSearch Hoʻonohonoho aloha ma o ka polokalamu kele pūnaewele Maʻalahi...