MOXA IKS-6728A-8PoE-4GTXSFP-HV-HV-T 24+4G-port Gigabit Modular Managed PoE Industrial Ethernet Switch

Wehewehe Pōkole:

Ua hoʻolālā ʻia ka IKS-6728A Series e hoʻokō i nā koi o nā noi koʻikoʻi no ka ʻoihana a me ka ʻoihana. Loaʻa i ka IKS-6728A a me IKS-6728A-8PoE a hiki i 24 10/100BaseT(X), a i ʻole PoE/PoE+, a me 4 mau awa Gigabit Ethernet combo. Hāʻawi nā kuapo Ethernet IKS-6728A-8PoE i 30 watts o ka mana no kēlā me kēia awa PoE+ ma ke ʻano maʻamau, a kākoʻo pū i ka mana kiʻekiʻe a hiki i 36 watts no nā mea hana PoE ʻoihana kaumaha, e like me nā kāmela kiaʻi IP pale i ka wā me nā wipers/heaters, nā wahi komo uea ʻole hana kiʻekiʻe, a me nā kelepona IP paʻa.

Kākoʻo nā kuapo Ethernet IKS-6728A-8PoE i ʻelua ʻano kumu hoʻokomo mana: 48 VDC no nā awa PoE+ a me ka mana ʻōnaehana, a me 110/220 VAC no ka mana ʻōnaehana. Kākoʻo pū kēia mau kuapo Ethernet i nā hana hoʻokele like ʻole, me STP/RSTP, Turbo Ring, Turbo Chain, hoʻokele mana PoE, nānā ponoʻī ʻana i ka hāmeʻa PoE, hoʻonohonoho mana PoE, diagnostic PoE, IGMP, VLAN, QoS, RMON, hoʻokele bandwidth, a me ke aniani ʻana i ke awa. Ua hoʻolālā kūikawā ʻia ka IKS-6728A-8PoE no nā noi waho paʻakikī me ka pale ʻana o ka piʻi ʻana o 3kV e hōʻoia i ka hilinaʻi ʻole o nā ʻōnaehana PoE.


Nā kikoʻī huahana

Nā Lepili Huahana

Nā Hiʻohiʻona a me nā Pōmaikaʻi

8 mau awa PoE+ i kūkulu ʻia e kūlike me IEEE 802.3af/at (IKS-6728A-8PoE)

A hiki i ka 36 W ka hoʻopuka no kēlā me kēia puka PoE+ (IKS-6728A-8PoE)

Apo Turbo a me ke kaulahao Turbo (manawa hoʻōla(<20 ms @ 250 kuapo), a me STP/RSTP/MSTP no ka redundancy pūnaewele

Ka palekana o ka piʻi ʻana o 1 kV LAN no nā wahi waho loa

Nā diagnostics PoE no ka loiloi ʻano hana mana

4 mau awa combo Gigabit no ke kamaʻilio bandwidth kiʻekiʻe

-40 a 75°C ka pae mahana hana ma 720 W ka hoʻouka piha

Kākoʻo iā MXstudio no ka hoʻokele pūnaewele ʻoihana maʻalahi a ʻike maka ʻia

Hoʻomaopopo ʻo V-ON™ i ka hoʻōla ʻana o ka ʻikepili multicast pae millisecond a me ka pūnaewele wikiō

ʻO ka pilina hoʻokomo/hoʻopuka

Nā Kanal Hoʻokaʻaʻike Alarm 1 hoʻopuka relay me ka mana lawe o kēia manawa o 1 A @ 24 VDC

ʻO ka pilina Ethernet

Nā awa 10/100BaseT(X) (mea hoʻohui RJ45) 8
Nā awa hui (10/100/1000BaseT(X) a i ʻole 100/1000BaseSFp) 4
Modula 2 mau kau modular no kekahi mau Modula Interface 8-port a i ʻole 6-port me 10/100BaseT(X), 100BaseFX (mea hoʻohui SC/ST), 100Base PoE/PoE+, a i ʻole 100Base SFP2
Nā Kūlana ʻO IEEE 802.1D-2004 no ka Spanning Tree Protocol

ʻO IEEE 802.1p no ka Papa HanaIEEE 802.1Q no ka VLAN Tagging

ʻO IEEE 802.1s no ka Protocol Lāʻau Spanning Nui

ʻO ka IEEE 802.1w no ka Rapid Spanning Tree Protocol

IEEE 802.1X no ka hōʻoia ʻana

IEEE802.3for10BaseT

ʻO IEEE 802.3ab no 1000BaseT(X)

ʻO IEEE 802.3ad no Port Trunk me LACP

ʻO IEEE 802.3u no 100BaseT(X) a me 100BaseFX

ʻO IEEE 802.3x no ka kaohi ʻana i ke kahe

ʻO IEEE 802.3z no 1000BaseSX/LX/LHX/ZX

Nā Palena Mana

Anakahi Hoʻokomo IKS-6728A-4GTXSFP-24-T: 24 VDCIKS-6728A-4GTXSFP-24-24-T: 24 VDC (nā mea hoʻokomo pālua keu)
IKS-6728A-4GTXSFP-48-T: 48 VDCIKS-6728A-4GTXSFP-48-48-T: 48 VDC (nā hoʻokomo pālua keu)
IKS-6728A-4GTXSFP-HV-T: 110/220 VAC

IKS-6728A-4GTXSFP-HV-HV-T: 110/220 VAC (nā mea hoʻokomo pālua keu) IKS-6728A-8PoE-4GTXSFP-48-T: 48 VDC

IKS-6728A-8PoE-4GTXSFP-48-48-T: 48 VDC (nā hoʻokomo pālua keu) IKS-6728A-8PoE-4GTXSFP-HV-T: 110/220 VAC

IKS-6728A-8PoE-4GTXSFP-HV-HV-T: 110/220 VAC (nā mea hoʻokomo pālua keu)

Anakahi Hana IKS-6728A-4GTXSFP-HV-T: 85 a i 264 VAC IKS-6728A-4GTXSFP-HV-HV-T: 85 a i 264VAC IKS-6728A-4GTXSFP-24-T: 18 a i 36 VDC IKS-6728A-4GTXSFP-24-24-T: 18 a i 36 VDC IKS-6728A-4GTXSFP-48-T: 36 a i 72 VDC IKS-6728A-4GTXSFP-48-48-T: 36 a i 72 VDC IKS-6728A-8PoE-4GTXSFP-48-48-T: 36 a i 72 VDC IKS-6728A-8PoE-4GTXSFP-HV-T: 85 a i 264 VAC IKS-6728A-8PoE-4GTXSFP-HV-HV-T: 85 a i 264VAC
Ka Palekana o ke Au Loa Kākoʻo ʻia
Ka Palekana Polarity Hoʻohuli Kākoʻo ʻia
Ke hoʻokomo nei i kēia manawa IKS-6728A-4GTXSFP-24-T/4GTXSFP-24-24-T: 0.36 A@24 VDCIKS-6728A-4GTXSFP-48-T/4GTXSFP-48-48-T: 0.19A@48 VDCIKS-6728A-8PoE-4GTXSFP-48-T/8PoE-4GTXSFP-48-48-T: 0.53 A@48 VDC

IKS-6728A-4GTXSFP-HV-T/4GTXSFP-HV-HV-T: 0.28/0.14A@110/220 VAC

IKS-6728A-8PoE-4GTXSFP-HV-T/8PoE-4GTXSFP-HV-HV-T: 0.33/0.24 A@110/220 VAC

Nā ʻano kino

Ka helu IP IP30
Nā Ana 440x44x280 mm (17.32x1.37x11.02 ʻīniha)
Kaumaha 4100g (9.05 lb)
Hoʻokomo ʻana Ke kau ʻana o ka pā

Nā Palena Kaiapuni

Mahana Hana -40 a i 75°C (-40 a i 167°F)
Ka Mahana Mālama (ua hoʻokomo ʻia ka pūʻolo) -40 a i 85°C (-40 a i 185°F)
Ka Haumākū Pili Ambient 5 a 95% (ʻaʻole e hoʻopili ʻia)

Nā Kumu Hoʻohālike i Loaʻa iā MOXA IKS-6728A-8POE-4GTXSFP-HV-HV-T

Kumu Hoʻohālike 1 MOXA IKS-6728A-4GTXSFP-24-24-T
Kumu Hoʻohālike 2 MOXA IKS-6728A-4GTXSFP-24-T
Kumu Hoʻohālike 3 MOXA IKS-6728A-4GTXSFP-48-48-T
Kumu Hoʻohālike 4 MOXA IKS-6728A-4GTXSFP-48-T
Kumu Hoʻohālike 5 MOXA IKS-6728A-4GTXSFP-HV-HV-T
Kumu Hoʻohālike 6 MOXA IKS-6728A-4GTXSFP-HV-T
Kumu Hoʻohālike 7 MOXA IKS-6728A-8PoE-4GTXSFP-48-48-T
Kumu Hoʻohālike 8 MOXA IKS-6728A-8PoE-4GTXSFP-48-T
Kumu Hoʻohālike 9 MOXA IKS-6728A-8PoE-4GTXSFP-HV-HV-T
Kumu Hoʻohālike 10 MOXA IKS-6728A-8PoE-4GTXSFP-HV-T

  • Ma mua:
  • Aʻe:

  • E kākau i kāu leka ma aneʻi a hoʻouna mai iā mākou

    Nā huahana pili

    • Kikowaena Hana Serial Rackmount ʻOihana MOXA NPort 5630-8

      MOXA NPort 5630-8 ʻOihana Rackmount Serial D...

      Nā Hiʻohiʻona a me nā Pōmaikaʻi Ka nui o ka rackmount maʻamau 19-'īniha Ka hoʻonohonoho maʻalahi o ka helu wahi IP me ka panela LCD (koe naʻe nā hiʻohiʻona wela ākea) E hoʻonohonoho ʻia e Telnet, polokalamu kele pūnaewele, a i ʻole ka pono Windows Nā ʻano socket: kikowaena TCP, mea kūʻai aku TCP, UDP SNMP MIB-II no ka hoʻokele pūnaewele Ka laulā voltage kiʻekiʻe honua: 100 a 240 VAC a i ʻole 88 a 300 VDC Nā laulā voltage haʻahaʻa kaulana: ±48 VDC (20 a 72 VDC, -20 a -72 VDC) ...

    • Kikowaena hāmeʻa hana hoʻopaʻa ʻoihana MOXA NPort IA5450A

      Mea hana hana ʻoihana MOXA NPort IA5450A...

      Hoʻolauna Ua hoʻolālā ʻia nā kikowaena hāmeʻa NPort IA5000A no ka hoʻopili ʻana i nā hāmeʻa serial automation ʻoihana, e like me nā PLC, nā sensor, nā mika, nā motika, nā drive, nā mea heluhelu barcode, a me nā hōʻikeʻike mea hoʻohana. Ua kūkulu paʻa ʻia nā kikowaena hāmeʻa, hele mai i loko o kahi hale metala a me nā mea hoʻohui wili, a hāʻawi i ka pale piha piha. He mea hoʻohana maʻalahi loa nā kikowaena hāmeʻa NPort IA5000A, e hana ana i nā hoʻonā serial-to-Ethernet maʻalahi a hilinaʻi hoʻi ...

    • ʻO Moxa ioThinx 4510 Series Advanced Modular Remote I/O

      ʻO Moxa ioThinx 4510 Series Advanced Modular Remot...

      Nā Hiʻohiʻona a me nā Pōmaikaʻi  Hoʻouka maʻalahi a wehe ʻole me ka mea hana  Hoʻonohonoho pūnaewele maʻalahi a me ka hoʻonohonoho hou ʻana  Hana puka komo Modbus RTU i kūkulu ʻia  Kākoʻo iā Modbus/SNMP/RESTful API/MQTT  Kākoʻo iā SNMPv3, SNMPv3 Trap, a me SNMPv3 Inform me ka hoʻopāʻālua SHA-2  Kākoʻo a hiki i 32 mau modula I/O  Loaʻa ka mahana hana ākea -40 a 75°C  Loaʻa nā palapala hōʻoia Class I Division 2 a me ATEX Zone 2 ...

    • MOXA EDS-G512E-8PoE-4GSFP Hoʻololi Ethernet ʻoihana Gigabit piha

      MOXA EDS-G512E-8PoE-4GSFP Hoʻokele Gigabit Piha ...

      Nā Hiʻohiʻona a me nā Pōmaikaʻi 8 IEEE 802.3af a me IEEE 802.3at PoE+ mau awa maʻamau 36-watt ka hoʻopuka no kēlā me kēia awa PoE+ ma ke ʻano mana kiʻekiʻe Turbo Ring a me Turbo Chain (manawa hoʻōla < 50 ms @ 250 mau kuapo), RSTP/STP, a me MSTP no ka redundancy pūnaewele RADIUS, TACACS+, MAB Authentication, SNMPv3, IEEE 802.1X, MAC ACL, HTTPS, SSH, a me nā helu wahi MAC sticky e hoʻonui i ka palekana pūnaewele Nā hiʻohiʻona palekana e pili ana iā IEC 62443 EtherNet/IP, PR...

    • Mea Hoʻohele Palekana ʻOihana MOXA EDR-810-2GSFP

      Mea Hoʻohele Palekana ʻOihana MOXA EDR-810-2GSFP

      MOXA EDR-810 Series ʻO ka EDR-810 kahi mea hoʻopili palekana multiport ʻoihana i hoʻohui nui ʻia me ka firewall/NAT/VPN a me nā hana hoʻololi Layer 2 i mālama ʻia. Ua hoʻolālā ʻia no nā noi palekana e pili ana iā Ethernet ma nā pūnaewele mana mamao koʻikoʻi a i ʻole ka nānā ʻana, a hāʻawi ia i kahi perimeter palekana uila no ka pale ʻana i nā waiwai cyber koʻikoʻi e pili ana i nā ʻōnaehana pump-and-treat ma nā kikowaena wai, nā ʻōnaehana DCS ma ...

    • Kikowaena Kikowaena Palekana MOXA NPort 6250

      Kikowaena Kikowaena Palekana MOXA NPort 6250

      Nā Hiʻohiʻona a me nā Pōmaikaʻi Nā ʻano hana palekana no Real COM, TCP Server, TCP Client, Pair Connection, Terminal, a me Reverse Terminal Kākoʻo i nā baudrates maʻamau ʻole me ka pololei kiʻekiʻe NPort 6250: Koho o ka medium pūnaewele: 10/100BaseT(X) a i ʻole 100BaseFX Hoʻonui ʻia ka hoʻonohonoho mamao me HTTPS a me SSH Port buffers no ka mālama ʻana i ka ʻikepili serial ke offline ka Ethernet Kākoʻo i nā kauoha serial IPv6 Generic i kākoʻo ʻia ma Com...