• poʻo_hae_01

MOXA IKS-6728A-4GTXSFP-HV-HV-T 24+4G-port Gigabit Modular Managed PoE Industrial Ethernet Switch

Wehewehe Pōkole:

Ua hoʻolālā ʻia ka IKS-6728A Series e hoʻokō i nā koi o nā noi koʻikoʻi no ka ʻoihana a me ka ʻoihana. Loaʻa i ka IKS-6728A a me IKS-6728A-8PoE a hiki i 24 10/100BaseT(X), a i ʻole PoE/PoE+, a me 4 mau awa Gigabit Ethernet combo. Hāʻawi nā kuapo Ethernet IKS-6728A-8PoE i 30 watts o ka mana no kēlā me kēia awa PoE+ ma ke ʻano maʻamau, a kākoʻo pū i ka mana kiʻekiʻe a hiki i 36 watts no nā mea hana PoE ʻoihana kaumaha, e like me nā kāmela kiaʻi IP pale i ka wā me nā wipers/heaters, nā wahi komo uea ʻole hana kiʻekiʻe, a me nā kelepona IP paʻa.

Kākoʻo nā kuapo Ethernet IKS-6728A-8PoE i ʻelua ʻano kumu hoʻokomo mana: 48 VDC no nā awa PoE+ a me ka mana ʻōnaehana, a me 110/220 VAC no ka mana ʻōnaehana. Kākoʻo pū kēia mau kuapo Ethernet i nā hana hoʻokele like ʻole, me STP/RSTP, Turbo Ring, Turbo Chain, hoʻokele mana PoE, nānā ponoʻī ʻana i ka hāmeʻa PoE, hoʻonohonoho mana PoE, diagnostic PoE, IGMP, VLAN, QoS, RMON, hoʻokele bandwidth, a me ke aniani ʻana i ke awa. Ua hoʻolālā kūikawā ʻia ka IKS-6728A-8PoE no nā noi waho paʻakikī me ka pale ʻana o ka piʻi ʻana o 3kV e hōʻoia i ka hilinaʻi ʻole o nā ʻōnaehana PoE.


Nā kikoʻī huahana

Nā Lepili Huahana

Nā Hiʻohiʻona a me nā Pōmaikaʻi

8 mau awa PoE+ i kūkulu ʻia e kūlike me IEEE 802.3af/at (IKS-6728A-8PoE)

A hiki i ka 36 W ka hoʻopuka no kēlā me kēia puka PoE+ (IKS-6728A-8PoE)

Apo Turbo a me ke kaulahao Turbo (manawa hoʻōla(<20 ms @ 250 kuapo), a me STP/RSTP/MSTP no ka redundancy pūnaewele

Ka palekana o ka piʻi ʻana o 1 kV LAN no nā wahi waho loa

Nā diagnostics PoE no ka loiloi ʻano hana mana

4 mau awa combo Gigabit no ke kamaʻilio bandwidth kiʻekiʻe

-40 a 75°C ka pae mahana hana ma 720 W ka hoʻouka piha

Kākoʻo iā MXstudio no ka hoʻokele pūnaewele ʻoihana maʻalahi a ʻike maka ʻia

Hoʻomaopopo ʻo V-ON™ i ka hoʻōla ʻana o ka ʻikepili multicast pae millisecond a me ka pūnaewele wikiō

ʻO ka pilina hoʻokomo/hoʻopuka

Nā Kanal Hoʻokaʻaʻike Alarm 1 hoʻopuka relay me ka mana lawe o kēia manawa o 1 A @ 24 VDC

ʻO ka pilina Ethernet

Nā awa 10/100BaseT(X) (mea hoʻohui RJ45) 8
Nā awa hui (10/100/1000BaseT(X) a i ʻole 100/1000BaseSFp) 4
Modula 2 mau kau modular no kekahi mau Modula Interface 8-port a i ʻole 6-port me 10/100BaseT(X), 100BaseFX (mea hoʻohui SC/ST), 100Base PoE/PoE+, a i ʻole 100Base SFP2
Nā Kūlana ʻO IEEE 802.1D-2004 no ka Spanning Tree Protoco

lIEEE 802.1p no ka Papa HanaIEEE 802.1Q no ka VLAN Tagging

ʻO IEEE 802.1s no ka Protocol Lāʻau Spanning Nui

ʻO ka IEEE 802.1w no ka Rapid Spanning Tree Protocol

IEEE 802.1X no ka hōʻoia ʻana

IEEE802.3for10BaseT

ʻO IEEE 802.3ab no 1000BaseT(X)

ʻO IEEE 802.3ad no Port Trunk me LACP

ʻO IEEE 802.3u no 100BaseT(X) a me 100BaseFX

ʻO IEEE 802.3x no ka kaohi ʻana i ke kahe

ʻO IEEE 802.3z no 1000BaseSX/LX/LHX/ZX

Nā Palena Mana

Anakahi Hoʻokomo IKS-6728A-4GTXSFP-24-T: 24 VDCIKS-6728A-4GTXSFP-24-24-T: 24 VDC (nā mea hoʻokomo pālua keu) IKS-6728A-4GTXSFP-48-T: 48 VDC
IKS-6728A-4GTXSFP-48-48-T: 48 VDC (nā hoʻokomo pālua keu) IKS-6728A-4GTXSFP-HV-T: 110/220 VAC
IKS-6728A-4GTXSFP-HV-HV-T: 110/220 VAC (nā mea hoʻokomo pālua keu) IKS-6728A-8PoE-4GTXSFP-48-T: 48 VDC
IKS-6728A-8PoE-4GTXSFP-48-48-T: 48 VDC (nā hoʻokomo pālua keu) IKS-6728A-8PoE-4GTXSFP-HV-T: 110/220 VAC
IKS-6728A-8PoE-4GTXSFP-HV-HV-T: 110/220 VAC (nā mea hoʻokomo pālua keu)
Anakahi Hana IKS-6728A-4GTXSFP-HV-T: 85 a i 264 VAC IKS-6728A-4GTXSFP-HV-HV-T: 85 a i 264VAC IKS-6728A-4GTXSFP-24-T: 18 a i 36 VDC IKS-6728A-4GTXSFP-24-24-T: 18 a i 36 VDC IKS-6728A-4GTXSFP-48-T: 36 a i 72 VDC IKS-6728A-4GTXSFP-48-48-T: 36 a i 72 VDC IKS-6728A-8PoE-4GTXSFP-48-48-T: 36 a i 72 VDC IKS-6728A-8PoE-4GTXSFP-HV-T: 85 a i 264 VAC IKS-6728A-8PoE-4GTXSFP-HV-HV-T: 85 a i 264VAC
Ka Palekana o ke Au Loa Kākoʻo ʻia
Ka Palekana Polarity Hoʻohuli Kākoʻo ʻia
Ke hoʻokomo nei i kēia manawa IKS-6728A-4GTXSFP-24-T/4GTXSFP-24-24-T: 0.36 A@24 VDCIKS-6728A-4GTXSFP-48-T/4GTXSFP-48-48-T: 0.19A@48 VDC
IKS-6728A-8PoE-4GTXSFP-48-T/8PoE-4GTXSFP-48-48-T: 0.53 A@48 VDC
IKS-6728A-4GTXSFP-HV-T/4GTXSFP-HV-HV-T: 0.28/0.14A@110/220 VAC
IKS-6728A-8PoE-4GTXSFP-HV-T/8PoE-4GTXSFP-HV-HV-T: 0.33/0.24 A@110/220 VAC

Nā ʻano kino

Ka helu IP IP30
Nā Ana 440x44x280 mm (17.32x1.37x11.02 ʻīniha)
Kaumaha 4100g (9.05 lb)
Hoʻokomo ʻana Ke kau ʻana o ka pā

Nā Palena Kaiapuni

Mahana Hana -40 a i 75°C (-40 a i 167°F)
Ka Mahana Mālama (ua hoʻokomo ʻia ka pūʻolo) -40 a i 85°C (-40 a i 185°F)
Ka Haumākū Pili Ambient 5 a 95% (ʻaʻole e hoʻopili ʻia)

Nā Kumu Hoʻohālike i Loaʻa iā MOXA IKS-6728A-4GTXSFP-HV-HV-T

Kumu Hoʻohālike 1 MOXA IKS-6728A-4GTXSFP-24-24-T
Kumu Hoʻohālike 2 MOXA IKS-6728A-4GTXSFP-24-T
Kumu Hoʻohālike 3 MOXA IKS-6728A-4GTXSFP-48-48-T
Kumu Hoʻohālike 4 MOXA IKS-6728A-4GTXSFP-48-T
Kumu Hoʻohālike 5 MOXA IKS-6728A-4GTXSFP-HV-HV-T
Kumu Hoʻohālike 6 MOXA IKS-6728A-4GTXSFP-HV-T
Kumu Hoʻohālike 7 MOXA IKS-6728A-8PoE-4GTXSFP-48-48-T
Kumu Hoʻohālike 8 MOXA IKS-6728A-8PoE-4GTXSFP-48-T
Kumu Hoʻohālike 9 MOXA IKS-6728A-8PoE-4GTXSFP-HV-HV-T
Kumu Hoʻohālike 10 MOXA IKS-6728A-8PoE-4GTXSFP-HV-T

  • Ma mua:
  • Aʻe:

  • E kākau i kāu leka ma aneʻi a hoʻouna mai iā mākou

    Nā huahana pili

    • MOXA ICS-G7850A-2XG-HV-HV 48G+2 10GbE Papa 3 Gigabit Piha Modular Hoʻokele ʻOihana Ethernet Kuapo

      MOXA ICS-G7850A-2XG-HV-HV 48G+2 10GbE Papa 3 F...

      Nā Hiʻohiʻona a me nā Pōmaikaʻi A hiki i 48 mau awa Gigabit Ethernet me 2 mau awa Ethernet 10G A hiki i 50 mau pilina fiber optical (nā ʻāpana SFP) A hiki i 48 mau awa PoE+ me ka lako mana waho (me ka module IM-G7000A-4PoE) Fanless, -10 a 60°C ka laulā mahana hana Hoʻolālā modular no ka maʻalahi loa a me ka hoʻonui ʻana i ka wā e hiki mai ana ʻAoʻao hoʻololi wela a me nā modula mana no ka hana mau Turbo Ring a me Turbo Chain...

    • Mea hoʻololi serial-to-fiber MOXA ICF-1150I-M-ST

      Mea hoʻololi serial-to-fiber MOXA ICF-1150I-M-ST

      Nā Hiʻohiʻona a me nā Pōmaikaʻi Kamaʻilio 3-ala: RS-232, RS-422/485, a me ka fiber Rotary switch e hoʻololi i ka waiwai resistor kiʻekiʻe/haʻahaʻa huki Hoʻonui i ka hoʻoili RS-232/422/485 a hiki i 40 km me ke ʻano hoʻokahi a i ʻole 5 km me ka multi-mode -40 a 85°C ākea-wela nā hiʻohiʻona i loaʻa C1D2, ATEX, a me IECEx i hōʻoia ʻia no nā ʻano ʻoihana ʻino Nā kikoʻī ...

    • Kikowaena Hana Serial Rackmount ʻOihana MOXA NPort 5610-16

      MOXA NPort 5610-16 ʻOihana Rackmount Serial ...

      Nā Hiʻohiʻona a me nā Pōmaikaʻi Ka nui o ka rackmount maʻamau 19-'īniha Ka hoʻonohonoho maʻalahi o ka helu wahi IP me ka panela LCD (koe naʻe nā hiʻohiʻona wela ākea) E hoʻonohonoho ʻia e Telnet, polokalamu kele pūnaewele, a i ʻole ka pono Windows Nā ʻano socket: kikowaena TCP, mea kūʻai aku TCP, UDP SNMP MIB-II no ka hoʻokele pūnaewele Ka laulā voltage kiʻekiʻe honua: 100 a 240 VAC a i ʻole 88 a 300 VDC Nā laulā voltage haʻahaʻa kaulana: ±48 VDC (20 a 72 VDC, -20 a -72 VDC) ...

    • Mea Hana Serial Laulā ʻOihana MOXA NPort 5232I

      Mea Hana Serial Laulā ʻOihana MOXA NPort 5232I

      Nā Hiʻohiʻona a me nā Pōmaikaʻi Hoʻolālā liʻiliʻi no ka hoʻokomo maʻalahi ʻana Nā ʻano Socket: kikowaena TCP, TCP client, UDP Pono hana Windows maʻalahi e hoʻohana no ka hoʻonohonoho ʻana i nā kikowaena hāmeʻa he nui ADDC (Automatic Data Direction Control) no 2-wire a me 4-wire RS-485 SNMP MIB-II no ka hoʻokele pūnaewele Nā kikoʻī Ethernet Interface 10/100BaseT(X) Ports (RJ45 connect...

    • Hoʻololi kuapo Ethernet ʻoihana i mālama ʻia ʻo MOXA MDS-G4028

      Hoʻololi kuapo Ethernet ʻoihana i mālama ʻia ʻo MOXA MDS-G4028

      Nā Hiʻohiʻona a me nā Pōmaikaʻi Nā ʻano interface like ʻole 4-port modules no ka versatility nui aʻe Hoʻolālā hana ʻole no ka hoʻohui a hoʻololi paha i nā modules me ka ʻole o ka pani ʻana i ke kuapo Nui ultra-compact a me nā koho kau ʻana he nui no ka hoʻonohonoho maʻalahi ʻana Backplane passive e hōʻemi i nā hana mālama Hoʻolālā die-cast paʻa no ka hoʻohana ʻana i nā wahi paʻakikī ʻO ka interface pūnaewele intuitive, HTML5 no kahi ʻike maʻalahi...

    • Mea Hana Serial Laulā ʻOihana MOXA NPort 5210

      Mea Hana Serial Laulā ʻOihana MOXA NPort 5210

      Nā Hiʻohiʻona a me nā Pōmaikaʻi Hoʻolālā liʻiliʻi no ka hoʻokomo maʻalahi ʻana Nā ʻano Socket: kikowaena TCP, TCP client, UDP Pono hana Windows maʻalahi e hoʻohana no ka hoʻonohonoho ʻana i nā kikowaena hāmeʻa he nui ADDC (Automatic Data Direction Control) no 2-wire a me 4-wire RS-485 SNMP MIB-II no ka hoʻokele pūnaewele Nā kikoʻī Ethernet Interface 10/100BaseT(X) Ports (RJ45 connect...